HP e3000/iX Network Planning and Configuration Guide (36922-90037)

Chapter 13 191
Configuring Logging
To Enable Users for Individual Logging Classes
To Enable Users for Individual Logging
Classes
The logging screens described previously in this chapter make it
possible to completely configure logging for all subsystems by
traversing only six screens. However, using these screens, it is not
possible to configure logging so that messages generated by specific
logging classes are sent to an individual user’s list device.
The following steps describe the method used to configure users to
receive logging messages. Using this method, you can create a
configuration that allows messages from a single logging class, or a set
of classes, to be sent to a user’s list device.
To do so, you access and update the Logging Configuration Class Data
screen (#67) in Figure 13-7, according to the steps that follow.
Figure 13-8 Logging Configuration: Class Data Screen
Step 1. Type the path name:
LOGGING.SUBnnnn.CLASnnnn
in the command window of any screen and press the
[ENTER] key, where
SUBnnnn is the subsystem ID and CLASnnnn is the class name of the
logging class you want directed to the user’s list device.