HP e3000 MPE/iX Release 6.0 System Software Maintenance Manual (30216-90272)
Table Of Contents
- Preface
- 1 Introduction
- 2 Task Checklists
- 3 Planning for Your Task
- 4 Preparing Your System
- 5 Modifying Your System
- 6 Finishing the Process
- A Manually Installed Products
- B Configuration Tables
- C Managing Disk Space
- D Backdating Your System
- E CD-ROM Resources
- F HP Patch/iX Reference
- G HP Stage/iX Reference
- H Error Messages and Warnings
- A

Appendix H 387
Error Messages and Warnings
Installer Error Messages (INSTERR)
• Contact the Response Center if further assistance is
required.
172 Message Purge of Relinker option file failed. (INSTERR
#172)
Cause Purge of a file with relinker options failed.
Action • Document any error message text prior to the error.
• Examine file for other accessors.
• If file is being accessed, free up file.
• Take appropriate corrective measures and run installer
again.
• Contact the Response Center if further assistance is
required.
173 Message Error setting the SOMPATCH jcw: PATCHJCW.
(INSTERR #173)
Cause The installer was attempting to set the SOMPATCH jcw:
PATCHJCW to a legal value prior to invoking
SOMPATCH to apply a binary patch.
Action • Document any error message text prior to the error.
• Issue the command SHOWVAR to determine if the
symbol table is full.
• Delete any user set variables or jcws.
• Run the installer again.
• Contact the Response Center if further assistance is
required.
174 Message The installer failed to build the ASYSUTIL file.
(INSTERR #174)
Cause Build of the ASYSUTIL file failed.
Action • Document any error message text prior to the error.
• If on old ASYSUTIL file exists, then purge it.
• Check for free disk space to build file. There are two
methods for obtaining additional disk space:
— Use the ALTERVOL command in VOLUTIL to set the
permanent and transient space allocation
assignments to 100% on all system volumes except
LDEV 1.
— Store user files to tape and them purge them.
Restore the files from tape at the end of the
installation.
• Take appropriate corrective measures and run the