HP e3000 MPE/iX Release 6.0 System Software Maintenance Manual (30216-90272)

Appendix H 369
Error Messages and Warnings
Installer Error Messages (INSTERR)
installer again.
Contact the Response Center if further assistance is
required.
98 Message The installer encountered an error while
monitoring
a streamed job. Error status returned by JobInfo
intrinsic: status
. (INSTERR #98)
Cause A call to the JOBINFO intrinsic failed while the installer
was attempting to obtain the number of a given job name
or to obtain the state of a job. The job in question should be
the last job streamed.
Action If the USL, UXL, UNL groups were not purged prior to
starting the installation, purge them and restart the
installation procedures.
Check the last streamed job's spoolfile, if it exists. The
jobs streamed by the installer are listed in the
HPINSTFL.INSTALL.SYS file.
Ensure the spooler has been started for the LP device.
Type LISTF I???????.USL.SYS.
If the file INDIRECT.USL.SYS exists, purge it, and run
the installer again.
Determine the current job from the HPINSTFL file and
check the JOB's existence and/or termination.
If the ifilename identified by HPINSTFL exists, inspect
that file for valid job commands. If this inspection
shows that the file is not a valid job, either purge the
file, or remove it from the USL.SYS group.
If the ifilename identified by HPINSTFL exists and
inspection of the file shows that the file is a valid job,
the file may be corrupted. Purge the file, and restore it
again from the SUBSYS tape.
Take appropriate corrective measures and run the
installer again.
Contact the Response Center if further assistance is
required.
99 Message Corrupt filename file. (INSTERR #99)
Cause Format of filename is unusable by the installer. Each line
should be a proper file equation format.
Action If the filename is SLTFEQ, purge SLTFEQ and
HPINSTFL files.