HP Data Entry and Forms Management System (VPLUS) Reference Manual (32209-90024)

Appendix B 553
VPLUS Error Messages
REFSPEC Messages
Menu Processing Errors
Error Message Cause/Action
501
Selection field cannot be
blank.
Enter one of the following codes in the MAIN
menu selection box: A, X, G, F, L, or D.
502
Reformat identifier ! not
found.
A reformat id entered on the MAIN menu is
not in the reformat file. Check the INPUT
FORMS menu or correct the identifier.
503
Output field name ! not found.
An output field name entered on the MAIN
menu is not in the reformat file. Check the
OUTPUT RECORD menus or correct the field
name.
504
No reformat identifier was
specified.
A selection on the MAIN menu requires a
reformat identifier. Enter the identifier or
change the selection.
505
There are no input form
sequences in the deleted was
specified.
A reformat identifier was specified, but no
INPUT FORMS reformat file. menu has been
entered.
506
No reformat to be deleted was
specified.
"D" was entered in MAIN menu selection box;
specify the reformat identifier to be deleted.
507
No such reformat identifier
exists.
A reformat identifier on the MAIN menu is
not on any INPUT FORMS menu.
508
Main selection field must be
"A!, "X", "G", "F", "L" or "D".
Enter one of the listed codes.
509
This field must be blank when
deleting.
The reformat id for deletion should be in the
right hand box; clear in the lefthand box.
510
Listing is not done on a field
level.
Enter "L" to list, and a reformat identifier in
the left hand box; you cannot list a single
field.
511
Form name must be blank for
compile.
When you enter "X" to compile the reformat
file, you cannot enter a reformat identifier.
512
Field name must be blank for
compile option.
When you enter "X" to compile the reformat
file, you cannot enter an output field name.
513
Form name is not specified when
adding a form.
When you enter "A" to add a reformat, do not
specify the reformat id; reformat id’s are
entered on the INPUT FORMS menu.
514
Fields are not added from the
MAIN menu.
Output fields are added on the OUTPUT
RECORD menu, not using the "A" option of
the MAIN menu.
515
Form name must be blank for
this option.
A selection was made on the MAIN menu that
cannot use a reformat id. Clear the reformat
id box.