HP Data Entry and Forms Management System (VPLUS) Reference Manual (32209-90024)
246 Chapter6
USING VPLUS INTRINSICS
COMMUNICATION AREA
• 2 - multifunction reader
• 3 - RS232 interface
• 4 - typeV badge reader
• 5 - magstripe reader
• 6 - bar code reader
• 7 - HP-IB interface
rightmodule
MPE determines which, if any, module is present.
• 0 - no module
• 1 - printer
• 2 - multifunction reader
• 3 - RS232 interface
• 4 - typeV badge reader
• 5 - magstripe reader
• 6 - bar code reader
• 7 - HP-IB interface
NOTE
VPLUS does not communicate with the RS-232 interface (3) or the HP-IB
interface (7).
keyboard
Type of keyboard used with terminal.
• 0 - HP 3077-no keyboard.
• 1 - standard keyboard (12 function keys with values of -1,0,17…26).
• 2 - alphanumeric keyboard (28 function keys with values of - 1,0…26).
display
Indicates the terminal type of display.
• 0 - numeric display
• 1 - alphanumeric display
• 2 - mini-CRT display
VPLUS does not support the terminal that has numeric display.
keyboardover
Two-byte integer determining whether to override input on the keyboard
or not. Default is 0.
• -1 - Override and enable the keyboard without regard to forms design.
• 0 - Do not override. Allow input from the devices specified during the
form design (in the Processing Specification area).
errorlight
Indicates which light to be turned on when an error is detected. The
default is E, but this can be changed to @ or any letter from A to P. The
second byte is reserved for system use.