Installation Manual

Configuring the HP Moonshot System 39
Configuring the HP Moonshot System
Chassis configuration overview
To configure the HP Moonshot System, complete the following:
Configure the chassis (on page 39).
Configure the switch (on page 41).
Configure the chassis
To configure the Moonshot 1500 chassis, complete the following steps:
1. Connect and configure a terminal for chassis configuration (on page 39).
2. Log in to the iLO CM firmware (on page 40).
3. Obtain the MAC addresses for each cartridge node (on page 40).
4. Configure the iLO CM firmware administrator account password (on page 40).
5. Update the firmware for the HP Moonshot System components (on page 40).
For detailed configuration information, see the following documents in the HP Moonshot Information Library
(http://www.hp.com/go/moonshot/docs):
o HP Moonshot iLO Chassis Management CLI User Guide
o HP Moonshot System Configuration and Compatibility Guide
Connect and configure a terminal for chassis configuration
To connect and configure a terminal to communicate with the iLO CM firmware:
1. Use a serial cable to connect a PC or terminal to the iLO CM management serial port on the Moonshot
1500 CM module. To locate the iLO CM management serial port, see "HP Moonshot 1500 Chassis
Management module components (on page 16)."
2. Configure the terminal with the following settings:
o 115200 baud rate
o 8 data bits
o No parity
o 1 stop bit
o No flow control
3. Start the terminal.