Array Diagnostics Utility
ADU collects all possible information about the array controllers in the system and
generates a list of detected problems. You can save this data to a file for analysis. In
most cases, ADU provides sufficient information for troubleshooting procedures.
To obtain ADU, download the utility from the HP website
www.hp.com
NetWare Online Array Configuration Utility
(CPQONLIN)
The NetWare Online Array Configuration Utility, also called CPQONLIN, is a
NetWare Loadable Module (NLM) for configuring drive arrays without shutting
down the server. CPQONLIN also provides information about the status of drives
attached to the Smart Array Cluster Storage Controller. It indicates drive failure,
expansion, or waiting for expansion or rebuild (queued). Before loading
CPQONLIN.NLM, you must load the appropriate device driversCPQFC.HAM and
CPQSHD.CDM. CPQONLIN.NLM is located in the ONLINE directory of Novell
SSD Disk 4.
IMPORTANT: CPQONLIN does not support SSP configurations. Use ACU 6.0 offline to
enable SSP configurations in a NetWare environment.