HP Smart Array Cluster Storage System
Display Messages
C-38 HP Smart Array Cluster Storage System User Guide
COMPAQ CONFIDENTIAL
Writer: Rob Weaver File Name: i-appc Display Messages
Codename: Aurora Part Number: 240333-003 Last Saved On: 11/8/02 3:50 PM
Table C-1: Display Messages continued
Message Type Description Action
406 STORAGE BOX
#<n> OVERHEATING
Error The temperature sensor
in the storage enclosure
indicates that the
enclosure is exceeding
the normal operating
range.
1. Power down the Smart
Array Cluster Storage
system as soon as
possible to avoid
hardware failure.
2. Be sure that all Smart
Array Cluster Storage
system fans are
operating.
3. Replace any failed
fans.
4. Be sure that all bays
are populated with
components or blanks.
If this action does not solve
the problem, contact HP
support.
407 STORAGE BOX
#<n> OVERHEATED
Error The temperature sensor
in the storage enclosure
indicates that the
enclosure exceeded the
safe operating range.
1. Power down the Smart
Array Cluster Storage
system as soon as
possible to avoid
hardware failure.
2. Be sure that all Smart
Array Cluster Storage
system fans are
operating.
3. Replace any failed
fans.
4. Be sure that all bays
are populated with
components or blanks.
If this action does not solve
the problem, contact HP
support.
continued