Table C-1: Display Messages continued
Message Type Description Action
202 ARRAY
CONTROLLER
OVERHEATING
Error The temperature sensor
on the array controller
indicates that the array
controller is exceeding
the normal operating
range.
1. Be sure that all Smart
Array Cluster Storage
system fans are
operating.
2. Replace any failed
fans.
3. Be sure that all bays
are populated with
components or blanks.
If this action does not solve
the problem, contact HP
support.
203 ARRAY
CONTROLLER
OVERHEATED
Error The temperature sensor
on the array controller
indicates that the array
controller exceeded the
safe operating range.
1. Power down the Smart
Array Cluster Storage
system as soon as
possible to avoid
hardware failure.
2. Be sure that all Smart
Array Cluster Storage
system fans are
operating.
3. Replace any failed
fans.
4. Be sure that all bays
are populated with
components or blanks.
If this action does not solve
the problem, contact HP
support.
continued