HP Smart Array Cluster Storage System

Display Messages
HP Smart Array Cluster Storage System User Guide C-29
COMPAQ CONFIDENTIAL
Writer: Rob Weaver File Name: i-appc Display Messages
Codename: Aurora Part Number: 240333-003 Last Saved On: 11/8/02 3:50 PM
Table C-1: Display Messages continued
Message Type Description Action
121 NO VOLUMES
DETECTED
Informational The controller did not
detect configured
volumes at power up.
If configured volumes are
expected at power up:
1. Power down the Smart
Array Cluster Storage
system.
2. Power down all
attached storage
enclosures.
3. Remove and reinstall
all SCSI drives, and be
sure that they seat fully
in their bays.
4. Check for proper
connections on the
cables between the
Smart Array Cluster
Storage system and
any attached storage
enclosures.
5. Power up the attached
storage enclosures.
6. Power up the Smart
Array Cluster Storage
system.
If this action does not solve
the problem, contact HP
support.
122 NEW
VOLUME(S)
DETECTED
Informational Configured volumes from
another array controller
were migrated to this
array controller. The
controller updated the
configuration information.
continued