HP Smart Array Cluster Storage System

Display Messages
C-24 HP Smart Array Cluster Storage System User Guide
COMPAQ CONFIDENTIAL
Writer: Rob Weaver File Name: i-appc Display Messages
Codename: Aurora Part Number: 240333-003 Last Saved On: 11/8/02 3:50 PM
Table C-1: Display Messages continued
Message Type Description Action
104 VOLUME #<n>
STATE DISABLED
Error The controller disabled
the configured volume
because too many of the
physical drives that
constitute the volume are
missing.
1. Power down the Smart
Array Cluster Storage
system.
2. Power down all
attached storage
enclosures.
3. Remove and reinstall
all SCSI drives, and be
sure that they seat fully
in their bays.
4. Check for proper
connections on the
cables between the
Smart Array Cluster
Storage system and
any attached storage
enclosures.
5. Power up the attached
storage enclosures.
6. Power up the Smart
Array Cluster Storage
system.
If this action does not solve
the problem, contact HP
support.
105 VOLUME #<n>
STATE EXPANSION
ACTIVE
Informational The configured volume is
performing a volume
expansion operation.
continued