HP Smart Array Cluster Storage System
Display Messages
C-22 HP Smart Array Cluster Storage System User Guide
COMPAQ CONFIDENTIAL
Writer: Rob Weaver File Name: i-appc Display Messages
Codename: Aurora Part Number: 240333-003 Last Saved On: 11/8/02 3:50 PM
Table C-1: Display Messages continued
Message Type Description Action
85 BAD DRIVE
FRMWARE BOX
#<n>, BAY <n>
Error A SCSI drive has corrupt
firmware. Continued use
of this drive could result
in drive failure,
decreased performance,
or data loss.
Do one of the following:
• Update the drive
firmware. Refer to
Chapter 3, “Hardware
Options Installation.”
• Replace the drive as
soon as possible. Refer
to “Recovering from
Hard Drive Failure” in
Appendix D.
If this action does not solve
the problem, contact HP
support.
86 DRIVE POSITION
CHANGE
DETECTED
Informational The physical drive
locations have changed
for SCSI drives that
constitute a configured
volume within the Smart
Array Cluster Storage
system or an attached
storage enclosure.
The array controller has
updated its configuration
information accordingly.
—
87 DRIVE POSITION
CHANGE INVALID
Informational
The physical drive
locations have changed
for SCSI drives that
constitute a configured
volume within the Smart
Array Cluster Storage
system or an attached
storage enclosure.
The array controller can
no longer access the
configured volume.
1. Power down the Smart
Array Cluster Storage
system.
2. Restore the drives to
their original positions.
If this action does not solve
the problem, contact HP
support.
continued