HP Smart Array Cluster Storage System

Display Messages
HP Smart Array Cluster Storage System User Guide C-21
COMPAQ CONFIDENTIAL
Writer: Rob Weaver File Name: i-appc Display Messages
Codename: Aurora Part Number: 240333-003 Last Saved On: 11/8/02 3:50 PM
Table C-1: Display Messages continued
Message Type Description Action
81 SMART DRIVE
ALERT BOX #<n>,
BAY <n>
Informational A SCSI drive may be
close to failing. The
prefailure condition was
determined either by the
drive firmware using
SMART technology or by
the array controller using
monitor and performance
testing.
Replace the drive as soon
as possible. Refer to
“Recovering from Hard
Drive Failure” in
Appendix D.
82 DRIVE HOT
ADDED BOX #<n>,
BAY <n>
Informational A SCSI drive has been
added to the Smart Array
Cluster Storage system
or to one of the storage
enclosures attached to it.
83 DRIVE HOT
REMOVED BOX
#<n>, BAY <n>
Informational A SCSI drive has been
removed from the Smart
Array Cluster Storage
system or from one of
the storage enclosures
attached to it.
84 DRIVE FAILURE
BOX #<n>, BAY <n>
Error A SCSI drive in the
Smart Array Cluster
Storage system or in one
of the storage enclosures
attached to it has failed.
If the drive was part of a
configured volume, the
state of the volume
depends on the fault
tolerance used.
Replace the drive as soon
as possible. Refer to
“Recovering from Hard
Drive Failure” in
Appendix D.
continued