HP Smart Array Cluster Storage System
Display Messages
C-16 HP Smart Array Cluster Storage System User Guide
COMPAQ CONFIDENTIAL
Writer: Rob Weaver File Name: i-appc Display Messages
Codename: Aurora Part Number: 240333-003 Last Saved On: 11/8/02 3:50 PM
Table C-1: Display Messages continued
Message Type Description Action
66 CACHE
HARDWARE FAILED
AND DISABLED
Error The cache memory has
experienced a hardware
failure.
If the Smart Array Cluster
Storage system is currently
involved in host I/O:
1. Remove the standby
array controller.
2. Wait 10 seconds.
3. Reinstall the controller,
and be sure that it
seats fully in the
chassis.
If this action does not solve
the problem, wait until
downtime is available and
do the following:
1. Power down the Smart
Array Cluster Storage
system.
2. Remove both array
controllers.
3. Reinstall both array
controllers, and be sure
that they seat fully in
the chassis.
If this action does not solve
the problem, contact HP
support.
continued