HP Smart Array Cluster Storage System

Display Messages
C-10 HP Smart Array Cluster Storage System User Guide
COMPAQ CONFIDENTIAL
Writer: Rob Weaver File Name: i-appc Display Messages
Codename: Aurora Part Number: 240333-003 Last Saved On: 11/8/02 3:50 PM
Table C-1: Display Messages continued
Message Type Description Action
49 REDUNDANCY
FAILED FIRMWARE
LOCKUP
Error While either attempting
to enter redundant mode
or already operating in
redundant mode, one of
the array controllers
encountered a critical
condition resulting in a
firmware lockup.
Redundancy is disabled
at this time.
If the Smart Array Cluster
Storage system is currently
involved in host I/O:
1. Remove the standby
array controller.
2. Wait 10 seconds.
3. Reinstall the controller,
and be sure that it
seats fully in the
chassis.
If this action does not solve
the problem, wait until
downtime is available and
do the following:
1. Power down the Smart
Array Cluster Storage
system.
2. Remove both array
controllers.
3. Reinstall both array
controllers, and be sure
that they seat fully in
the chassis.
If this action does not solve
the problem, contact HP
support.
continued