HP Smart Array Cluster Storage System
Cluster Installation and Configuration
HP Smart Array Cluster Storage System User Guide 5-33
HP CONFIDENTIAL
Writer: Rob Weaver File Name: f-ch5 Cluster Installation and Configuration
Codename: Aurora Part Number: 240333-003 Last Saved On: 11/6/02 1:05 PM
7. During operating system installation, select New Installation for the install type
so that you can specify disk partitions suited for LifeKeeper for Linux.
8. When installation is complete, the Congratulations screen appears. You can
configure additional hardware at this time. Click Finish Installation to reboot
the server.
9. Install the Linux Driver for the Smart Array 5i, 5300 Series for SuSE-SLES7.
Refer to
www.compaq.com/support/files/server/us/index.html
NOTE: This Linux driver is also known as the CCISS driver.
10. Install, if necessary, the Array Configuration Utility, which can be used for
online configurations. Refer to
www.compaq.com/support/files/server/us/index.html
11. Power down the server.
12. Repeat steps 2 through 11 for the second server.
Installing Management Agents for Servers for Linux
For instructions on installing and running Agents for Server for Linux, refer to
www.compaq.com/support/files/server/us/WebDoc/550/Linux.pdf
Configuring the Storage System
To configure the storage system:
1. Boot one server from the SmartStart CD Version 6.1 or later.
2. After the server boots, click the Maintenance tab, then select and run the Array
Configuration Utility.
3. From the ACU Configuration screen, select the Smart Array Cluster
Controller to configure the storage system hard drives. Refer to the HP Array
Configuration Utility User Guide on the Documentation CD.