Technical data
Troubleshooting
Dealing with HPMC (Uncorrectable Error)
4-19
To identify the failed FRU(s) after an HPMC, follow these steps:
1 Examine the “Other Processor Data” words returned from the PIM command
to display the latest error information from the last TOC, LPMC, or HPMC interruption
detected.
2 Compare the values from the PIM command with those shown in Table 4-4 and take
the appropriate action.
Table 4-4 PIM Action Table
Check
Type Word
Cache
Check
Word
Bus Check
Word
System
Responder
Word
Action
0x80000000 0x40000000 N/A N/A Replace CPU board
0x20000000 N/A 0x00210003 0x00000000
0xEFFFFFF
Refer to Determin-
ing the Faulty
Memory Card, later
in this chapter.
0x20000000 N/A 0x00310007 0xF0000000
0xF01FFFFF
Replace CPU
board.
0x20000000 N/A 0x00310007 0xF0200000
0xF0207FFF
Replace EISA tray,
if present, or
replace CPU board.
0x20000000 N/A 0x00310007 0xF0280000
0xF029FFFF
Replace PCMCIA
adapter. If problem
persists replace
CPU board.
0x20000000 N/A 0x00310007 0xF0300000
0xF031FFFF
Replace CPU
board.
0x20000000 N/A 0x00310007 0xF0400000
0xF3FFFFFF
Check VME system
configuration and/
or replace CPU
board.