Specifications
Removal and Replacement Procedures
HP ProLiant ML330 Generation 3 Server Maintenance and Service Guide 2-37
Re-entering the Server Serial Number
After replacing the system board or clearing the NVRAM, the server serial number must be
re-entered.
1. During the server startup sequence, press the F9 key to access RBSU.
2. Select
the System Options menu.
3. Select Serial Number. The following warning is disp
layed:
WARNING! WARNING! WARNING! The serial number is loaded into the
system during the manufacturing process and should NOT be
modified. This option should ONLY be used by qualified service
personnel. This value should always match the serial number
sticker located on the chassis.
Press the Enter key to clear the warning.
4. Enter the serial number and press the Enter key.
5. Press the Escape key to close the menu.
6. Press the Escape key to exit RBSU.
7. Press
the F10 key to confirm exiting RBSU. The server will automatically reboot.