Windows Server 2008 R2 and Windows Server 2008 R2 with Service Pack 1 on HP Integrity Servers Release Notes v7.1
Servers Superdome SX2000, rx8640, rx7640, rx6600, rx3600, rx2660
Workaround Manually reboot the system. HP is aware of this issue.
SCSI
Event ID 129 errors on Integrity blade servers
Issue HP Integrity blade servers with the embedded 1068 SAS controller that are using
the in-box driver (revision 1.28.03.51) for the embedded SAS controller can see
excessive Event ID 129 errors.
Servers HP Integrity BL860c Server Blade and BL870c Server Blade
Workaround Download and install the 01.28.03.65 or later driver from http://www.hp.com.
Smart Array
Blue screen displays when Smart Array cards are hot removed
Issue A blue screen is displayed when Smart Array P800/E500 and P400 cards are
hot removed with no storage attached.
Servers All supported Integrity servers
Workaround HP does not recommend any hot replace or hot add functions for these cards.
System Management Homepage (SMH)
Unexpected termination message in System Event Log
Issue After upgrading Windows Server 2008 R2 to Service Pack 1, you might see the
following message in the Windows System Event Log during the required shutdown
of the system:
The HP System Management Homepage terminated unexpectedly.
Servers All supported Integrity servers
Workaround None. This event does not affect the operation of HP System Management
Homepage; you can ignore the message.
Video
HP SUM screen cannot be resized
Issue When installing the Integrity Service Pack (ISP), the HP SUM screen cannot be
resized.
Servers rx2660
Workaround Before running HP SUM, install the HP Integrity Video driver smart component
(cp011254.exe) before installing the Integrity Support Pack.