Smart Array Internal Cabling Guide
Cabling for the HP Integrity rx8620 Server
HP Smart Array Controller Card Ports
Chapter 1
2
HP Smart Array Controller Card Ports
The ports on the HP Smart Array Controller Cards are labeled as shown in Table 1-2
When a port is referenced in this document the following notation is used (See Figure 1-1 for additional
information):
Installing the HP Smart Array Controller Card
Step 1. If the server is running, shut down the OS, power off the server, and unplug the power cords.
Step 2. Remove the top cover of the server.
Step 3. If only one HP Smart Array controller card is to be installed, install it into slot 8 of IO Chassis 0 for
internal RAID configuration.
Step 4. If two HP Smart Array controller cards are to be installed, install them into slots 8 of IO Chassis 0
and IO Chassis 1 for internal RAID configuration.
NOTE The HP Smart Array controller card must be installed in PCI slot 8 for internal
RAID configurations. If another PCI card is located in slot 8, that card must be
relocated to another slot.
Table 1-2 HP Smart Array Controller Card Port Labels
Controller Card Port Location
SA 5302/SA5304 Port 1 Port near bulkhead
Port 2 Port near center of card
SA 6402/SA6404 Port A2 Port near bulkhead
Port A1 Port near center of card
Table 1-3 Port Identification Notation
Notation Port Location
Port 1/A2 Port near bulkhead
Port 2/A1 Port near center of
card