Management Agents Events Reference

Event DescriptionEvent SeverityEvent ID
Too many edges were encountered during a procedure call. Data Field: link count.
Probable Cause: There was a problem while collecting a list of fabric link info.
Recommended Action: Look for additional IPMI event logs. Contact your HP Support
Representative to analyze the fabric. SNMP Trap: hpevtManyEdgEncntProcCall -
10941 in HPIFPTRAP.MIB.
Warning10941
Failed to get an address during a procedure call. Data Field: return status. Probable
Cause: Failed to get a fabric address. Recommended Action: Look for additional IPMI
event logs. Contact your HP Support Representative to analyze the fabric. SNMP
Trap: hpevtFailGetAddrProcCall - 10943 in HPIFPTRAP.MIB.
Warning10943
An unexpected state was encountered during a procedure call. Data Field: state
returned. Probable Cause: System Firmware encountered an unknown fabric link
state. Recommended Action: Capture IPMI event logs. Contact your HP Support
Representative to analyze the fabric link. SNMP Trap: hpevtUnexpctStatEncntProcCall
- 10944 in HPIFPTRAP.MIB.
Warning10944
Unable to get the link health state during a procedure call. Data Field: return status.
Probable Cause: System Firmware was unable to read the fabric port's Fatal Error
state. The link may or may not be in error. Recommended Action: Collect IPMI event
logs for further details. Contact your HP Support Representative to analyze the fabric.
SNMP Trap: hpevtUnablGetLnkHlthStatProcCall - 10945 in HPIFPTRAP.MIB.
Warning10945
The fabric data failed a CRC check. Data Field: (xbc port 44 ) | (xbc 32) | return status).
Probable Cause: The fabric data structure may have been corrupted. Recommended
Action: Collect IPMI event logs. Contact your HP support representative to investigate
the health of the system. SNMP Trap: hpevtFabDatFailCrcChk - 10946 in
HPIFPTRAP.MIB.
Warning10946
VM_CollectVertices failed unexpectedly. Could possibly be a data corruption problem.
Data field: (cell number 56) | (return value from VM_CollectVertices). Probable
Cause: An error occurred while routing the fabric, possible data corruption or
firmware error. Recommended Action: Contact your HP support representative to
inspect the fabric and system firmware. SNMP Trap: hpevtVmCollVertcFailUnexpct
- 11032 in HPIFPTRAP.MIB.
Warning11032
Unable to generate an ALB address in Arches Fabric ArfSetDefaultCSRs() function.
Data field:(cell number 56) | (port number 48) | (xbc ID 32) | (return value). Probable
Cause: An error occurred while routing the fabric, possible data corruption or
firmware error. Recommended Action: Contact your HP support representative to
inspect the fabric and system firmware. SNMP Trap: hpevtUnablGenAlbArfSetCsr
- 11033 in HPIFPTRAP.MIB.
Warning11033
SetDefaultCSRs function failed unexpectedly. Arches Fabric was unable to set XBC
CSRs to default values. Data field: return value from SetDefaultCSRs. Probable Cause:
An error occurred while routing the fabric. Recommended Action: Collect IPMI event
logs, and contact your HP support representative to inspect the fabric and system
firmware. SNMP Trap: hpevtSetDefCsrFailUnexpct - 11034 in HPIFPTRAP.MIB.
Warning11034
A problem was encountered while routing which prevented an appropriate route
from being chosen. Data Field: Destination Cell 56 | XBC Port 44 | XBC # 32 | return
status. Probable Cause: An error occurred while routing the fabric. Recommended
Action: Contact your HP support representative to inspect the fabric and system
firmware. SNMP Trap: hpevtEncntErrRout - 11038 in HPIFPTRAP.MIB.
Warning11038
An error was encountered while routing the fabric. This error prevents an appropriate
route from being selected. Data Field: Destination Cell 56 | XBC Port 44 | XBC # 32
| return status. Probable Cause: An error occurred while routing the fabric.
Recommended Action: Contact your HP support representative to inspect the fabric
and system firmware. SNMP Trap: hpevtEncntErrRoutFab - 11039 in
HPIFPTRAP.MIB.
Warning11039
Platform Agent Events 85