Management Agents Events Reference
Event DescriptionEvent SeverityEvent ID
System Firmware was unable to access the configured set stored in the complex
profile. Probable Cause: SFW was unable to access the configured set stored in the
complex profile. Recommended Action: Collect IPMI events and contact your HP
Support Representative. SNMP Trap: hpevtSysFwUnAccesComplxProf - 10481 in
HPIFPTRAP.MIB.
Warning10481
System Firmware detected an error during Fabric Init. Probable Cause: Error detected
by SFW during Fabric Init. Recommended Action: Collect IMPI events and contact
your HP Support Representative for assistance. SNMP Trap:
hpevtSysFwDetctErrFabInit - 10482 in HPIFPTRAP.MIB.
Warning10482
System Firmware detected a failure during Fabric Init. Probable Cause: Failure
detected by SFW during Fabric Init. Recommended Action: Collect IPMI events and
contact your HP Support Representative for assistance. SNMP Trap:
hpevtSysFwDetctFailFabInit - 10483 in HPIFPTRAP.MIB.
Warning10483
System Firmware detected an error during Fabric Optimize. Probable Cause: Error
detected by SFW during Fabric Optimize. Recommended Action: Collect IMPI events
and contact your HP Support Representative for assistance. SNMP Trap:
hpevtSysFwDetctErrFabOptimz - 10487 in HPIFPTRAP.MIB.
Warning10487
Input power to the specified UPS has failed. SNMP Trap: hpevtInPwrUPSFail - 10489
in HPIFPTRAP.MIB.
Warning10489
Input power to the specified UPS has been restored. SNMP Trap: hpevtUpsRestored
- 10490 in HPIFPTRAP.MIB.
Warning10490
UPS power exhausted. The system is being powered down. SNMP Trap:
hpevtUpsExhausted - 10495 in HPIFPTRAP.MIB.
Error10495
During Machine Check handling, SAL failed to rendezvous all the processors.
Probable Cause: System firmware cannot roundup the processors during the machine
check handler. Recommended Action: Check for faulty processor, possibly the one(s)
that failed to rendezvous. Contact your HP representative for support. SNMP Trap:
hpevtSALFailRedzvsProcs - 10509 in HPIFPTRAP.MIB.
Warning10509
SAL failed to clear the CEC logs during Machine check handling. Probable Cause:
System firmware failed to clear the CEC logs. Recommended Action: Check for
multiple errors or bad CEC. Contact your HP representative for support. SNMP Trap:
hpevtSALFailClrCECLog - 10510 in HPIFPTRAP.MIB.
Warning10510
System FW was unable to access the XBC semaphore. Probable Cause: System FW
was unable to access the XBC semaphore. Recommended Action: Collect IPMI events,
look for additional errors events, and contact HP support for assistance. SNMP Trap:
hpevtSysFwUnAccesXBCSemphr - 10516 in HPIFPTRAP.MIB.
Warning10516
System Firmware detected an error while trying to release the XBC Global Semaphore.
Probable Cause: Error detected by SFW while trying to release the XBC Global
Semaphore. Recommended Action: Collect IPMI events and contact your HP Support
Representative. SNMP Trap: hpevtSysFwDetctErrRelXBCGlobSemphr - 10518 in
HPIFPTRAP.MIB.
Warning10518
System Firmware detected an Error while checking the owner of the XBC Global
Semaphore. Probable Cause: Error detected by SFW while checking the owner of the
XBC Global Semaphore. Recommended Action: Collect IMPI events and contact your
HP Support Representative. SNMP Trap: hpevtSysFwDetctErrOwnXBCGlobSemphr
- 10519 in HPIFPTRAP.MIB.
Warning10519
An error occurred while forming the XBC semaphore address. Probable Cause:
Couldn't determine the proper address of the XBC semaphore. Recommended Action:
Save IPMI event codes, contact HP Support Representative to analyze the fabric
SNMP Trap: hpevtErrFormXbcSemphrAddr - 10520 in HPIFPTRAP.MIB.
Warning10520
Error reading the XBC Global Semaphore. Probable Cause: Couldn't read the XBC
semaphore. Recommended Action: Look for additional IPMI event logs, contact your
HP support representative to analyze the fabric SNMP Trap:
hpevtErrRdXbcGlobSemphr - 10521 in HPIFPTRAP.MIB.
Warning10521
78 Management Agents Event Tables