Management Agents Events Reference

Event DescriptionEvent SeverityEvent ID
Error reading Skyline ALREC_ALB_ID CSR. Data field: (Skyline port) | (Cell number
56). Probable Cause: System firmware was unable to read a fabric hardware register.
Recommended Action: Capture IPMI event logs, look for additional errors. Contact
your HP Support Representative to analyze the fabric SNMP Trap:
hpevtErrRdAlrecAlbIdCsr - 10389 in HPIFPTRAP.MIB.
Warning10389
A circular route was found while testing XBC CSR traffic traversability. Data field:
(target XBC 32) | (cellNum 56). Probable Cause: Internal firmware error, fabric was
routed incorrectly. Recommended Action: Capture IPMI event logs, look for additional
errors. Contact your HP Support Representative to analyze the fabric SNMP Trap:
hpevtCirRoutFndTstXbcCsr - 10390 in HPIFPTRAP.MIB.
Warning10390
Error reading ALREC_ALB_ID CSR for an XBC port. Data field: (xbcNum 32) |
(portNum 48). Probable Cause: System firmware was unable to read a fabric hardware
register. Recommended Action: Capture IPMI event logs, look for additional errors.
Contact your HP Support Representative to analyze the fabric SNMP Trap:
hpevtXBCRdErrAlrecAlbIdCsr - 10391 in HPIFPTRAP.MIB.
Warning10391
An XBC-XBC port had an invalid chip type connection. Data field: (expected chip
type) | (actual chip type 32). Probable Cause: System firmware found a discrepancy
in the system topology. Recommended Action: Capture IPMI event logs, look for
additional errors. Contact your HP Support Representative to analyze the fabric
SNMP Trap: hpevtXBC-XBCPrtHavInvldChipCnn - 10392 in HPIFPTRAP.MIB.
Warning10392
ArfIsXbcRouteTraversable was called on a back-to-back system which is an improper
use of the function. Data field: unused. Probable Cause: Internal firmware error.
Recommended Action: Capture IPMI event logs, look for additional errors. Contact
your HP Support Representative to analyze the fabric SNMP Trap:
hpevtArflsXbcRotTravrsblCalBakToBak - 10393 in HPIFPTRAP.MIB.
Warning10393
In ArfIsXbcRouteTraversable, an XBC-XBC link was found to have fatal errors. Data
field: (xbcNum 32) | (portNum 48). Probable Cause: A previously healthy link was
found to have fatal errors. Recommended Action: Capture IPMI event logs, look for
additional errors. Contact your HP Support Representative to analyze the fabric
SNMP Trap: hpevtXBCToXBClnkFndFatErr - 10394 in HPIFPTRAP.MIB.
Warning10394
Unable to read the XBC ROUTE_TABLE_ENABLE_MASK CSR. Data field: (xbcNum
32) | (portNum 48). Probable Cause: System firmware was unable to read a fabric
hardware register. Recommended Action: Capture IPMI event logs, look for additional
errors. Contact your HP Support Representative to analyze the fabric SNMP Trap:
hpevtUnablRdXbcRotTblEnblMskCsr - 10395 in HPIFPTRAP.MIB.
Warning10395
Error reading an XBC ROUTE_TABLE CSR. Data field: route index | (xbcNum 32)
| (portNum 48). Probable Cause: System firmware was unable to read a fabric
hardware register. Recommended Action: Capture IPMI event logs, look for additional
errors. Contact your HP Support Representative to analyze the fabric SNMP Trap:
hpevtErrRdXbcRotTablCsr - 10396 in HPIFPTRAP.MIB.
Warning10396
Error reading ALB ALREC_ALB_ID CSR for an XBC port. Data field: (xbcNum 32)
| (portNum 48). Probable Cause: System firmware was unable to read a fabric
hardware register. Recommended Action: Capture IPMI event logs, look for additional
errors. Contact your HP Support Representative to analyze the fabric SNMP Trap:
hpevtXbcPrtErrRdAlrecAlbIDCsr - 10397 in HPIFPTRAP.MIB.
Warning10397
An XBC port was found with an unexpected neighbor chip. Data field: expected chip
type | (actual chip type 32). Probable Cause: System firmware found a discrepancy
in the expected system topology. Recommended Action: Capture IPMI event logs,
look for additional errors. Contact your HP Support Representative to analyze the
fabric SNMP Trap: hpevtXbcPrtFndUnxpctNgbrChip - 10398 in HPIFPTRAP.MIB.
Warning10398
A cell/port pair was not found in the expected graph data. Data field: (cellNum 32)
| CC portNum. Probable Cause: Internal firmware error or data corruption.
Recommended Action: Capture IPMI event logs, look for additional errors. Contact
your HP Support Representative to analyze the fabric SNMP Trap:
hpevtCelPrtPairNotFndGrphDat - 10401 in HPIFPTRAP.MIB.
Warning10401
Platform Agent Events 75