Event DescriptionEvent SeverityEvent ID
The system firmware had an error with the structured error handling mechanism.
Probable Cause: Either there is an error in the system firmware or the system firmware
has exhausted all resources. Recommended Action: Invalidate NVM or check for
newer version of system firmware. SNMP Trap: hpevtIoErrengineError - 9486 in
HPIFPTRAP.MIB.
Error9486
Not enough malloc resources for I/O structure error handling. Probable Cause: Either
invalidate NVM or check for a new version of system firmware. SNMP Trap:
hpevtIoDiscEeMallocErr - 9487 in HPIFPTRAP.MIB.
Error9487
Unable to create entry for I/O structure error handling. Probable Cause: This is a
system firmware error, either invalidate NVM or check for a newer version of system
firmware. SNMP Trap: hpevtIoDiscEeCreatetreeErr - 9488 in HPIFPTRAP.MIB.
Error9488
Unable to bind services for I/O structure exception handling. Probable Cause: This
is a system firmware error. Either reset NVM or check for a newer version of system
firmware. SNMP Trap: hpevtIoDiscEeAttachserviceErr - 9489 in HPIFPTRAP.MIB.
Error9489
Error initializing the I/O structure exception handling services. Probable Cause: This
is a system firmware error. Either reset NVM or check for a newer version of system
firmware. SNMP Trap: hpevtIoDiscEeInitErr - 9490 in HPIFPTRAP.MIB.
Error9490
Error initializing structured I/O exception data structures. Probable Cause: This is a
system firmware error, there is a conflict with system resources. Either reset NVM
or check for a newer version of system firmware. SNMP Trap:
hpevtIoDiscEeInitializationErr - 9491 in HPIFPTRAP.MIB.
Error9491
The I/O exception context has an error. Probable Cause: This is a system firmware
error. Reset the system, invalidate NVM and reset the system, or check for a newer
version of the system firmware. SNMP Trap: hpevtIoDiscEeContextErr - 9492 in
HPIFPTRAP.MIB.
Error9492
Error creating the internal data and services for the SBA. Probable Cause: This is a
system firmware error. Reset the system; invalidate NVM and reset the system; or
check for a newer version of system firmware. SNMP Trap:
hpevtIoDiscCreateSbaNodeErr - 9493 in HPIFPTRAP.MIB.
Error9493
Error attaching the services to the SBA internal data structures. Probable Cause: This
is a system firmware error. Reset the partition; invalidate NVM on the reporting cell
and reset the system; or check for a newer version of system firmware. SNMP Trap:
hpevtIoDiscSbaAttachserviceErr - 9494 in HPIFPTRAP.MIB.
Error9494
Error initializing the internal SBA data and services. Probable Cause: This is a system
firmware error. Reset the partition; invalidate NVM on the reporting cell and reset
the partition; or check for newer system firmware. SNMP Trap:
hpevtIoDiscSbaInitnodeErr - 9495 in HPIFPTRAP.MIB.
Error9495
The SBA type is unknown to the system firmware. Probable Cause: This is either a
system firmware error, or the wrong I/O is connected to the system. Validate the
system recipe both firmware and hardware. SNMP Trap: hpevtIoDiscSbaUnknownErr
- 9496 in HPIFPTRAP.MIB.
Error9496
An embedded I/O device is missing. Probable Cause: Replaces the I/O card specified
by the physical location. SNMP Trap: hpevtIoDeviceMissing - 9497 in
HPIFPTRAP.MIB.
Warning9497
Fabric link route around failed because the route around port was bad. Probable
Cause: 2 or more XBC links are not routable. Recommended Action: Contact HP
Support personnel to check the XBC, Flex Cables, Backplane, CCs, etc SNMP Trap:
hpevtFabricRmtRoutePortBadReroute - 9498 in HPIFPTRAP.MIB.
Warning9498
Predictive Failure in Memory. Probable Cause: You will receive this message if the
memory system is observing a lot of corrected ECC errors from a DIMM. The specified
DIMM may need to be serviced. Recommended Action: Contact your HP support
representative to check the affected hardware. SNMP Trap: hpevtAgtPredictMemFail
- 9652 in HPIFPTRAP.MIB.
Warning9652
Platform Agent Events 65