Management Agents Events Reference
Event DescriptionEvent SeverityEvent ID
MPON failed to release. Probable Cause: A hardware fault has occurred.
Recommended Action: Contact HP Support personnel to troubleshoot the Cell Board,
Cell Power Board and PDH Daughtercard. SNMP Trap: hpevtPdhcMponFailed -
9390 in HPIFPTRAP.MIB.
Error9390
Dillon failed to reset. Probable Cause: Hardware failure. Recommended Action: Fix
the hardware, pdh riser or cell. SNMP Trap: hpevtPdhcDillonResetFailed - 9391 in
HPIFPTRAP.MIB.
Error9391
DMD clock is not running. Probable Cause: A hardware fault has occurred.
Recommended Action: Contact HP Support personnel to troubleshoot the Cell Board,
Cell Power Board and PDH Daughtercard. SNMP Trap: hpevtPdhcDmdClockFailed
- 9392 in HPIFPTRAP.MIB.
Error9392
All cpus on the Cell are scheduled to be deconfigured. Probable Cause: All cpus on
the cell have been scheduled for deconfiguration. On the next reset, the cell will no
longer be operational; system firmware will deconfigure all the cpus and this cell
will not be part of a partition. This action is not recommended. To recover, the
NVRAM on the PDH card must be cleared, the cell power cycled, and defaults
restored from disk. SNMP Trap: hpevtAllCpusDeconfOnCell - 9394 in
HPIFPTRAP.MIB.
Error9394
A read error occurred while dumping the routing registers. Probable Cause: Fabric
Read Error. Recommended Action: Check XBC, CC, links, etc. SNMP Trap:
hpevtFabricLogRoutingRdErr - 9403 in HPIFPTRAP.MIB.
Error9403
Failed to disable the CC to CC link. Probable Cause: Failure to read or write CC CSRs.
Recommended Action: Contact HP Support personnel to check the Check CC. SNMP
Trap: hpevtFabricLinkRendezDisableErr - 9412 in HPIFPTRAP.MIB.
Error9412
Power has been removed from AC input A0. Probable Cause: A power source has
been removed from the chassis. SNMP Trap: hpevtAcDeletedA0 - 9417 in
HPIFPTRAP.MIB.
Warning9417
Power has been removed from AC input A1. Probable Cause: A power source has
been removed from the chassis. SNMP Trap: hpevtAcDeletedA1 - 9418 in
HPIFPTRAP.MIB.
Warning9418
Power has been removed from AC input B0. Probable Cause: A power source has
been removed from the chassis. SNMP Trap: hpevtAcDeletedB0 - 9419 in
HPIFPTRAP.MIB.
Warning9419
Power has been removed from AC input B1. Probable Cause: A power source has
been removed from the chassis. SNMP Trap: hpevtAcDeletedB1 - 9420 in
HPIFPTRAP.MIB.
Warning9420
Failed to disable the XIN link during a failed link init. Probable Cause: Have your
HP Support Representative check the Coherency Controller SNMP Trap:
hpevtFabricCc2CcLinkDisableErr - 9428 in HPIFPTRAP.MIB.
Warning9428
Error copying the routing registers to the local port. Probable Cause: XBC access
failure. Recommended Action: Check XBC, check links, check backplane, check CC.
SNMP Trap: hpevtFabricISREarlyCopyRoutingErr - 9430 in HPIFPTRAP.MIB.
Error9430
Error while reading the remote CC's XIN Error Mask register. Probable Cause: CC
access failure. Recommended Action: Contact HP Support personnel to check the
CC. SNMP Trap: hpevtFabricClrLinkInitBitErrMaskRd - 9431 in HPIFPTRAP.MIB.
Warning9431
Error clearing the init packet received bit in the XIN error mask. Probable Cause: CC
access failure. Recommended Action: PDC Reviewed alert level for SR - 9/6/03 CC.
SNMP Trap: hpevtFabricClrLinkInitBitErrMaskWr - 9432 in HPIFPTRAP.MIB.
Warning9432
Failed to read the XBC's Port Status register. Probable Cause: fabric access failure.
Recommended Action: Check XBC, Check CC, Check backplane SNMP Trap:
hpevtFabricPortPairRdPstatusErr - 9433 in HPIFPTRAP.MIB.
Warning9433
62 Management Agents Event Tables