Management Agents Events Reference
Event DescriptionEvent SeverityEvent ID
The bulk specified is warning of a potential thermal problem. Probable Cause: The
bulk power supply is warning of an over temperature condition SNMP Trap:
hpevtBpsWarnOt - 8818 in HPIFPTRAP.MIB.Warning8818
Malloc failed while trying to process and ERM. Probable Cause: Heap space is
completely used or corrupt. Contact Product Engineering. SNMP Trap:
hpevtErmOutOfHeap - 8819 in HPIFPTRAP.MIB.Error8819
Dimm at physical location in data field is not supported on this platform. Probable
Cause: Unsupported dimm in specified slot. Recommended Action: Replace dimm
with supported dimm. SNMP Trap: hpevtMemDimmUnsupported - 8821 in
HPIFPTRAP.MIB.Warning8821
The OPTIONS component received a memory allocation error. Probable Cause:
Invalidate NVRAM and reset. SNMP Trap: hpevtOptsMallocError - 8828 in
HPIFPTRAP.MIB.Error8828
A dimm or CPU has been deconfigured or failed testing. Probable Cause: A
deconfigured dimm or cpu has been detected. Examine earlier events to isolate the
problem. SNMP Trap: hpevtCellHwDegraded - 8837 in HPIFPTRAP.MIB.Warning8837
The cell will not join the PD. Probable Cause: Broken hardware was detected and
the cell integration policy combined to cause the cell to not join the PD. Recommended
Action: Fix the broken hardware or change the policy using parmgr. If assistance is
required, contact the HP Support Center. SNMP Trap: hpevtNotIntegratingCell -
8839 in HPIFPTRAP.MIB.Error8839
The error context in NVM was corrupt. Probable Cause: NVM is corrupted.
Recommended Action: Check for other errors in the system first. Invalidate NVM
and retry boot. Get the latest firmware release. SNMP Trap: hpevtIoContextCorruptErr
- 8842 in HPIFPTRAP.MIB.Warning8842
A rope went fatal from the SBA. Probable Cause: Mainly a hardware problem causes
this problem. Recommended Action: Replace I/O chassis. SNMP Trap:
hpevtIoRopeFatal - 8843 in HPIFPTRAP.MIB.Warning8843
A PCI bus on the system went fatal. Probable Cause: A bad card, a bad device, or a
system hardware problem can cause this to occur. Card will be powered off (if
possible) and the attention light on the slot will be lit indicating an error.
Recommended Action: Reseat Card. Replace Card. If error persists, contact HP
support. SNMP Trap: hpevtIoBusFatal - 8844 in HPIFPTRAP.MIB.Warning8844
One of the rope units in the SBA is dead. Probable Cause: Usually hardware. SNMP
Trap: hpevtIoRopeUnitFatal - 8845 in HPIFPTRAP.MIB.Warning8845
The System Flash Write Enable bit is incorrectly set and now clearing by PDC.
Probable Cause: The System Flash Write Enable bit is incorrectly set by hardware
and now cleared by PDC. Recommended Action: If this chassis code occurs in every
boot then contact HP Support personnel to troubleshoot the problem. SNMP Trap:
hpevtPdhFlashWriteEnableBitSetNowCleared - 8851 in HPIFPTRAP.MIB.Warning8851
Firmware encountered a problem trying to initialize. Probable Cause: Examine the
related event that failed and correct that problem. SNMP Trap:
hpevtFirmwareInitError - 8855 in HPIFPTRAP.MIB.Error8855
This means that all the cpus in the cell did not show up. Probable Cause: This will
result in the cell stepping independently to collect its logs and resting itself. SNMP
Trap: hpevtMcIncompleteCpuSet - 8857 in HPIFPTRAP.MIB.Warning8857
This means that all the cells did not rendezvous during the PD rendezvous. Probable
Cause: The cells will reset themselves. SNMP Trap: hpevtMcIncompleteCellSet - 8858
in HPIFPTRAP.MIB.Warning8858
The FW tree sanity check failed during the MCA error processing. Probable Cause:
The cells will independently log errors and reset. SNMP Trap:
hpevtMcTreeCheckFailed - 8859 in HPIFPTRAP.MIB.Warning8859
Platform Agent Events 55