Management Agents Events Reference

Event DescriptionEvent SeverityEvent ID
Memory platform data update failure. Probable Cause: Memory FW was unable to
save or restore the original error configuration. Recommended Action: If this is seen,
update SFW. SNMP Trap: hpevtMemPlatformInitFailure - 5218 in HPIFPTRAP.MIB.Warning5218
Can't find memory rank entry. Probable Cause: The rank structure that corresponds
to the rankID in the data field could not be found in the Rank table, possibly due to
NVM corruption. Recommended Action: Contact HP support to troubleshoot the
problem. SNMP Trap: hpevtMemRankEntryNotFound - 5219 in HPIFPTRAP.MIB.Warning5219
Memory error overflow:. Probable Cause: An error other than a memory error
occurred during the memory test. Recommended Action: Contact HP support to
troubleshoot the problem SNMP Trap: hpevtMemTestExcessMcBits - 5237 in
HPIFPTRAP.MIB.Warning5237
Memory forward progress code invalid. Probable Cause: The forward progress bits
are invalid. Recommended Action: Upgrade to latest system firmware, or contact
HP support to troubleshoot the problem. SNMP Trap:
hpevtMemTestFwdProgBitsInvalid - 5238 in HPIFPTRAP.MIB.Warning5238
Memory error status invalid. Probable Cause: Non-memory errors were detected
during the memory test that FW doesn't know how to handle. Recommended Action:
Update to the latest SFW. Recommended Action: Contact HP support to troubleshoot
the problem. SNMP Trap: hpevtMemTestStatusBitsInvalid - 5244 in HPIFPTRAP.MIB.Warning5244
Memory error summary bits invalid. Probable Cause: The memory test summary
word is invalid. Recommended Action: Update to the latest SFW. Recommended
Action: Contact HP support to troubleshoot the problem. SNMP Trap:
hpevtMemTestSummaryBitsInvalid - 5245 in HPIFPTRAP.MIB.Warning5245
Unexpected machine check during memory code. Probable Cause: Incompatible
memory controller and memory DIMM. Recommended Action: Update system board
with current memory controller. SNMP Trap: hpevtMemUnexpectedMca - 5248 in
HPIFPTRAP.MIB.Error5248
The DIMM distribution check was bypassed. Probable Cause: Control bit to skip
DIMM distribution check is set. Recommended Action: Clear NVM. Recommended
Action: Update PDC. Recommended Action: Contact HP support to troubleshoot
the problem SNMP Trap: hpevtMemWarnDistributionCheckBypass - 5250 in
HPIFPTRAP.MIB.Warning5250
The DIMM Loading Order check was bypassed. Probable Cause: Control bit to skip
DIMM loading order check is set. Recommended Action: Clear NVM. Recommended
Action: Update PDC. Recommended Action: Contact HP support to troubleshoot
the problem SNMP Trap: hpevtMemWarnLoadingOrderBypass - 5252 in
HPIFPTRAP.MIB.Warning5252
Looping on destructive memory tests. Probable Cause: Control bit to loop on
destructive memory test is set. Recommended Action: Clear NVM. Recommended
Action: Update PDC. Recommended Action: Contact HP support to troubleshoot
the problem SNMP Trap: hpevtMemWarnLoopOnDestTest - 5253 in HPIFPTRAP.MIB.Warning5253
DIMM Set Check has been skipped. Probable Cause: Control bit to skip DIMM set
check is set. Recommended Action: Clear NVM. Recommended Action: Update PDC.
Recommended Action: Contact HP support to troubleshoot the problem SNMP Trap:
hpevtMemWarnSetCheckBypass - 5255 in HPIFPTRAP.MIB.Warning5255
Serial Presence Detect (SPD) has been skipped. Probable Cause: Control bit to skip
DIMM SPD check is set. Recommended Action: Clear NVM. Recommended Action:
Update PDC. Recommended Action: Contact HP support to troubleshoot the problem
SNMP Trap: hpevtMemWarnSpdBypass - 5256 in HPIFPTRAP.MIB.Warning5256
An Alternate Memory Config has been loaded into the system. Probable Cause:
Control bit to use an alternate memory config are set. Recommended Action: Clear
NVM Update SFW Contact HP support to troubleshoot the problem SNMP Trap:
hpevtMemWarnUsingAltConfig - 5257 in HPIFPTRAP.MIB.Warning5257
Platform Agent Events 21