Management Agents Events Reference

Event DescriptionEvent SeverityEvent ID
Expected I/O host bridge is missing . Probable Cause: I/O host bridge failure. An
incorrect I/O backplane is installed. Recommended Action: Contact your HP
representative to check the I/O host bridge and the I/O backplane. SNMP Trap:
hpevtIoCheckLbaMissingErr - 5123 in HPIFPTRAP.MIB.Warning5123
LBA has unexpected number of I/O slots. Probable Cause: The firmware needs to be
updated. An incorrect I/O backplane is installed. Recommended Action: Contact
your HP representative to check the firmware and the I/O backplane. SNMP Trap:
hpevtIoCheckNumSlotsErr - 5124 in HPIFPTRAP.MIB.Warning5124
I/O rope width does not match expected value. Probable Cause: The firmware needs
to be updated. An incorrect I/O backplane is installed. Recommended Action: Update
SFW. If problem persists, contact your HP representative to check the I/O backplane.
SNMP Trap: hpevtIoCheckRopeWidthErr - 5125 in HPIFPTRAP.MIB.Warning5125
Found unexpected I/O host bridge. Probable Cause: The firmware needs to be
updated. An incorrect I/O backplane is installed. Recommended Action: Update
SFW. If problem persists, contact your HP representative to check the I/O backplane.
SNMP Trap: hpevtIoCheckXtraLbaFoundErr - 5127 in HPIFPTRAP.MIB.Warning5127
PCI clock DLL error. Probable Cause: Failed I/O chipset. Failed I/O backplane.
Recommended Action: Contact your HP representative to check the I/O chipset and
backplane. SNMP Trap: hpevtIoDllError - 5130 in HPIFPTRAP.MIB.Warning5130
PCI hot plug controller failed. Probable Cause: Hot-plug controller failure. I/O host
bridge failure. Recommended Action: Contact your HP representative to check the
hot-plug controller and the I/O host bridge. SNMP Trap: hpevtIoHotPlugCtrlFailed
- 5131 in HPIFPTRAP.MIB.Warning5131
Found unknown I/O rope width. Probable Cause: Internal firmware error.
Recommended Action: Contact your HP representative to check the firmware. SNMP
Trap: hpevtIoInvalidRopeBundle - 5132 in HPIFPTRAP.MIB.Warning5132
I/O LBA clear error failed. Probable Cause: I/O host bridge failure. Recommended
Action: Contact your HP representative to check the I/O host bridge. SNMP Trap:
hpevtIoLbaClearErrFailed - 5133 in HPIFPTRAP.MIB.Warning5133
I/O host bridge inaccessible because rope reset failed to complete. Probable Cause:
I/O CEC failure. Recommended Action: Contact your HP representative to check the
I/O CEC. SNMP Trap: hpevtIoLbaResetError - 5136 in HPIFPTRAP.MIB.Warning5136
Insufficient power to turn on PCI slot. Probable Cause: The power budget for the IO
subsystem has been exceeded. Recommended Action: The IO config in the system
is unsupported. Verify that the IO config installed in the system is one that is
supported. If problem persists contact your HP representative for support. SNMP
Trap: hpevtIoNotEnoughPowerError - 5137 in HPIFPTRAP.MIB.Warning5137
PCI bus walk unknown error. Probable Cause: Internal firmware error. Recommended
Action: Contact your HP representative to check the firmware. SNMP Trap:
hpevtIoPciMappingFailed - 5138 in HPIFPTRAP.MIB.Warning5138
PCI bus walk resources exceeded. Probable Cause: Unsupported I/O configuration.
Recommended Action: Remove any unsupported I/O cards. Move the I/O card to
another slot. SNMP Trap: hpevtIoPciMappingTooBig - 5139 in HPIFPTRAP.MIB.Warning5139
PCI bus unmap unknown error. Probable Cause: Internal firmware error.
Recommended Action: Contact your HP representative to check the firmware. SNMP
Trap: hpevtIoPciUnmappingFailed - 5140 in HPIFPTRAP.MIB.Warning5140
PCIXCAP sampling error. Probable Cause: I/O host bridge failure. Recommended
Action: Contact your HP representative to check the I/O host bridge. SNMP Trap:
hpevtIoPcixcapSampleError - 5141 in HPIFPTRAP.MIB.Warning5141
Power monitor failed to respond. Probable Cause: BMC failure. Recommended
Action: Contact your HP representative to check the BMC. SNMP Trap:
hpevtIoPmNotRespondingError - 5142 in HPIFPTRAP.MIB.Warning5142
Platform Agent Events 17