Management Agents Events Reference

Event DescriptionEvent
Severity
Event ID
The IDE Agent could not open a mutex. The data contains the error code.Warning3594
The IDE Agent could not create its main thread of execution. The data contains the
error code.
Warning3595
The IDE Agent main thread did not terminate properly. The data contains the error
code.
Warning3596
The IDE Agent got an unexpected error code while waiting for an event. The data
contains the error code.
Warning3597
The IDE Agent got an unexpected error code while waiting for multiple events. The
data contains the error code.
Warning3598
The IDE Agent did not respond to a request. The data contains the error code.Warning3599
The IDE Agent received an unknown action code from the service. The data contains
the action code.
Warning3600
The Remote Alerter Agent detected an invalid datatype within an alert definition.Warning768
The Remote Alerter Agent detected an error while attempting to log an alert remotely.
The data contains the error code.
Warning769
The Remote Alerter Agent was unable to log an event in the event log of the system
named %1. The data contains the error code.
Warning771
The Remote Alerter Agent detected a null handle on initialization. The data contains
the error code.
Error772
The Remote Alerter Agent received an error on WaitForMultipleObjects call. The
data contains the error code.
Error773
The Remote Alerter Agent received an error on ResetEvent call. The data contains
the error code.
Error774
Error: Could not read from the registry subkey. Cause: This error can be caused by
a corrupt registry or a low memory condition. Rebooting the server may correct this
error.
Warning4609
Error: Could not write the registry subkey: "%1". Cause: This error can be caused by
a corrupt registry or a low memory condition. Rebooting the server may correct this
error.
Warning4610
Error: Could not read the registry subkey: "%1". Cause: This error can be caused by
a corrupt registry or a low memory condition. Rebooting the server may correct this
error.
Warning4611
Error: Could not read the registry subkey: "%1". Cause: This error can be caused by
a corrupt registry or a low memory condition. Rebooting the server may correct this
error.
Warning4612
Error: Could not read the registry subkey: "%1". Cause: This error can be caused by
a corrupt registry or a low memory condition. Rebooting the server may correct this
error.
Warning4613
SCSI Controller Status Change.%nThe SCSI controller in slot %4, SCSI bus %5 has a
new status of %2.%n(Controller status values: 1=other, 2=ok, 3=failed)%n[SNMP
TRAP: 5005 in CPQSCSI.MIB]
Error1068
SCSI Logical Drive Status Change.%nThe SCSI logical drive with SCSI target %6
connected to SCSI bus %5 of the controller in slot %4 has a new status of %2.%n(Drive
status values: 1=other, 2=ok, 3=failed, 4=unconfigured, 5=recovering,
6=readyForRebuild, 7=rebuilding, 8=wrongDrive, 9=badConnect, 10=degraded,
11=disabled)%n [SNMP TRAP: 5021 in CPQSCSI.MIB]
Error1069
Storage Agent Events 121