Management Agents Events Reference

Event DescriptionEvent
Severity
Event ID
The IPMI device driver attempted to communicate with the IPMI BMC device during
normal operation. However the communication failed due to a timeout. You can try
increasing the timeouts associated with the IPMI device driver located in the registry
at
HKLM\SYSTEM\CurrentControlSet\Control\IPMI\CommandWaitTimeoutPeriod,
between 5000000 to 10000000 usec, the default is 5000000 usec.
Error1004
\Device\CpqHlth, The Hewlett Packard IPMI device driver was loaded.Informational2000
The Hewlett Packard IPMI device driver could not load. NTSTATUS return code is
shown in data field. Make sure you have the latest version of the driver.
Error2001
The IPMI device driver could not open the IML soft log in the windows registry: %2.
Make sure HP Insight Management Agents or HP Insight Management WBEM
Providers are installed.
Warning2002
HpMcaLog (MCA Monitor Service) Events
Event DescriptionEvent SeverityEvent ID
%1 Failed to initialize service: %2. %3 %1 - "[component name]" %2 - "Error code =
error code" %3 - "See log file for details."
Error106
%1 Could not register with the Service Control Manager. %2 %1 - "[component name]"
%2 - "See log file for details.
Error113
%1 Could not set the service status with the Service Control Manager. %2 %1 -
"[component name]" %2 - "See log file for details.
Error114
%1 WMI usage error. %2 %1 - "[component name]" %2 - "See log file for details.Error126
HpPfmSvc (Pre-Fail Monitor Service) Events
Event DescriptionEvent
Severity
Event ID
A Corrected Machine Check (or Corrected Platform Error) error of an unknown
variety was observed by the PreFail Monitor. This error was corrected and no action
is necessary, but if this condition repeats contact HP for support guidance.
Warning1
HP PFM has detected an invalid HP PFM rules file. As the result, default monitoring
threshold values are being used. Please contact HP support team to solve this problem.
Warning1
HP PFM service detected the DIMM module in %s has been added.Informational2
HP PFM service detected the DIMM module in %s has been removed.Informational2
HP PFM service detected the DIMM module in %s has been replaced.Informational2
HP PFM has detected a module replacement: The DIMM %s has been replaced. The
serial number of the older module was %s and the serial number of the newer is %s.
Informational2
HP PFM service detected the CPU module in %s has been added.Informational2
HP PFM service detected the CPU module in %s has been removed.Informational2
HP PFM service detected the CPU module in %s has been replaced.Informational2
HP PFM has detected a module replacement: The CPU %s has been replaced. The
serial number of the older module was %s and the serial number of the newer is %s.
Informational2
The Predictive Failure Monitor sub-service version %s has startedInformational2
HpMcaLog (MCA Monitor Service) Events 111