INIT Initiated. Probable Cause: The critical interrupt sensor has detected that there
was a Diagnostic Interrupt initiated by IPMI command. Either the Transfer Of Control
(TOC) button was pressed or the interrupt was initiated remotely. The system will
reboot after the interrupt processing is finished. Recommended Action: If this is
unexpected behavior, then check logs for events that would have caused an INIT,
TOC, or RESET. SNMP Trap: SystemHW - 746 in HPIFP02TRAP.MIB.Error746
PCI system error detected. Probable Cause: An I/O device (or host bridge) detected
an internal error. OR An I/O device (or host bridge) detected a bus error.
Recommended Action: For an I/O device failure, consult the error logs for additional
information. Determine and replace the failed I/O device. For an I/O host bridge
failure, contact your HP representative to check the I/O host bridge. SNMP Trap:
SystemHW - 747 in HPIFP02TRAP.MIB.Warning747
OS run-time critical shutdown. Probable Cause: The OS caused the system to shut
down. Recommended Action: Look at OS logs and crash data to determine why the
system shut down. SNMP Trap: SystemHW - 748 in HPIFP02TRAP.MIB.Error748
ACPI state S5 (soft-off, entered by override). Probable Cause: The system has been
powered OFF with a hard power-down. Recommended Action: HP recommends
that when you powered down the system you use the normal shutdown procedure
to properly shut down the operating system. Otherwise, data-loss and/or hardware
failure can occur. SNMP Trap: SystemHW - 749 in HPIFP02TRAP.MIB.Warning749
PCI parity error detected. Probable Cause: An I/O device (or host bridge) detected a
bus parity error, OR An I/O device (or host bridge) mastered a bus transaction and
received a parity error response from the target. Recommended Action: For an I/O
bus parity error, consult the error logs for additional information. Determine and
replace the failed I/O device. For an I/O host bridge failure, contact your HP
representative to check the I/O host bridge. SNMP Trap: SystemHW - 751 in
HPIFP02TRAP.MIB.Warning751
Temperature sensor crossed lower non-critical threshold. Probable Cause: The
temperature inside the server has gone outside the factory specified range for normal
operation. You should quit applications and power down the server to protect its
hardware from damage. This event may indicate one of the following conditions: A
failed fan, blocked air vents or poor ventilation around the server, open server chassis
cover, or missing drive slot covers, high temperature in the room where the server
resides, an unusually hot hardware component located near one of the server's
temperature sensors. Recommended Action: Find cause of temperature anomaly and
fix it. SNMP Trap: hpTempHighWarning - 752 in HPIFP02TRAP.MIB.Warning752
A temperature inside the server went far outside the factory specified range. Probable
Cause: The temperature inside the server has gone far outside the factory specified
range for normal operation. To avoid permanent damage to your server hardware,
go and turn off the server immediately. This event may indicate one of the following
conditions: a failed fan blocked air vents or poor ventilation around the server open
server chassis cover, or missing drive slot covers high temperature in the room where
the server resides an unusually hot hardware component located near one of the
server's temperature sensors. Recommended Action: Find cause of temperature
anomaly and fix it. SNMP Trap: hpTempHighCritical - 753 in HPIFP02TRAP.MIB.Error753
Temperature sensor crossed upper non-recoverable threshold. Probable Cause: The
temperature inside the server has gone far outside the factory specified range for
normal operation. To avoid permanent damage to your server hardware, go and
turn off the server immediately. This event may indicate one of the following
conditions: a failed fan blocked air vents or poor ventilation around the server open
server chassis cover, or missing drive slot covers high temperature in the room where
the server resides an unusually hot hardware component located near one of the
server's temperature sensors. Recommended Action: Find cause of temperature
anomaly and fix it. SNMP Trap: hpTempHighNonRecoverable - 754 in
HPIFP02TRAP.MIB.Error754