HP Integrity Servers with Microsoft® Windows Server™ 2003 and Windows Server™ 2008 Management Agents Events Reference Guide HP Part Number: 5992-5590 Published: May 2009
© Copyright 2008 Hewlett-Packard Development Company, L.P. Legal Notices Confidential computer software. Valid license from HP required for possession, use or copying. Consistent with FAR 12.211 and 12.212, Commercial Computer Software, Computer Software Documentation, and Technical Data for Commercial Items are licensed to the U.S. Government under vendor's standard commercial license. The information contained herein is subject to change without notice.
Table of Contents About This Document.........................................................................................................5 Intended Audience.................................................................................................................................5 New and Changed Information in This Edition.....................................................................................5 Document Organization.....................................................................
About This Document This document describes the Windows System Log Event ID number, severity, and description of events generated by the HP Integrity Management Agents software on HP Integrity servers running Microsoft® Windows® Server 2003 and Windows® Server 2008. The document printing date and part number indicate the document’s current edition. The printing date changes when a new edition is printed. Minor changes may be made at reprint without changing the printing date.
Ctrl+x A key sequence. A sequence such as Ctrl+x indicates that you must hold down the key labeled Ctrl while you press another key or mouse button. Related Information You can find more information about HP Integrity servers, server management, and software in the following locations: • For an overview of the HP Integrity server family: http://hp.com/go/integrity • For other documents supporting Windows Server 2003 and Windows Server 2008 on HP Integrity Servers: http://docs.hp.com/en/hw.
1 Management Agents Event Tables Introduction This reference guide describes the Windows System Log Event ID number, severity, and description of events generated by HP Integrity Management Agents software. The Management Agents are a group of services that run continuously in the background on HP Integrity servers and report the status of system components. Each Management Agent has its own unique table in this document.
Event ID 8 9 10 12 26 113 518 699 8 Event Severity Event Description Error A measured voltage in the server has gone far outside the factory specified lower voltage range. Probable Cause: The voltage in the server has gone outside the factory set range. A bad component, blown fuse, poorly seated module, loose cable, or debris could be responsible for this failure. Recommended Action: Check all boards, power supplies, and modules that either supply or use this voltage rail.
Event ID 700 704 705 706 707 710 720 722 726 728 729 Event Severity Event Description Error Generic trap for Critical or Fatal type E0 event from system firmware. Probable Cause: This event is generated when a critical or fatal event has occurred as reported by system firmware. The server is not operational and is in a state where it cannot provide more details about the failure.
Event ID 730 731 732 733 734 735 736 737 738 739 740 744 745 10 Event Severity Event Description Error The BMC firmware did not detect the system firmware boot. Probable Cause: Possible Causes: 1. Bad System Firmware image in ROM 2. Power not reaching processors 3. Processor is in reset or is not properly seated in system 4. An unsupported processor was inserted in system 5. Communication with BMC is impaired. Recommended Action: To correct the problem, try the following: 1.
Event ID 746 747 748 749 751 752 753 754 Event Severity Event Description Error INIT Initiated. Probable Cause: The critical interrupt sensor has detected that there was a Diagnostic Interrupt initiated by IPMI command. Either the Transfer Of Control (TOC) button was pressed or the interrupt was initiated remotely. The system will reboot after the interrupt processing is finished.
Event ID 755 756 757 758 5001 5002 5003 5010 5011 5013 5023 5025 12 Event Severity Event Description Warning One of the temperature sensors crossed its upper non-critical threshold. Probable Cause: The temperature inside the server has gone outside the factory specified range for normal operation. You should quit applications and power down the server to protect its hardware from damage.
Event ID 5027 5028 5030 5031 5033 5034 5036 5037 5040 5041 5042 5045 5048 5049 Event Severity Event Description Error Boot cell virtualize SAL failure. Probable Cause: SFW was unable to virtualize SAL. Recommended Action: Reboot, if problem persists contact your HP representative for support. SNMP Trap: hpevtBootCellVirtualizeSalFailure - 5027 in HPIFPTRAP.MIB. Error Boot cell virtualize SALPROC failure. Probable Cause: SFW was unable to virtualize SALPROC.
Event ID Error External interruption nest limit exceeded. Probable Cause: Internal FW error. Recommended Action: Reboot, if problem persists contact your HP representative for support. SNMP Trap: hpevtBootExtIntNestLimitedExceeded - 5050 in HPIFPTRAP.MIB. Error External interrupt not serviced. Probable Cause: Internal FW error. Recommended Action: Reboot, if problem persists contact your HP representative for support. SNMP Trap: hpevtBootExtIntNotServiced - 5051 in HPIFPTRAP.MIB. Error Ext int taken.
Event ID Event Severity Event Description Error PAL_B not in FIT table. Probable Cause: Internal Error or ROM is corrupted. Recommended Action: Reboot, if problem persists contact your HP representative for support. SNMP Trap: hpevtBootNoPalBInFit - 5069 in HPIFPTRAP.MIB. Error SAL_B not in FIT table. Probable Cause: Internal Error or ROM is corrupted. Recommended Action: Reboot, if problem persists contact your HP representative for support. SNMP Trap: hpevtBootNoSalBInFit - 5070 in HPIFPTRAP.MIB.
Event ID 5098 5100 5101 5102 5103 5104 5105 5106 5107 5108 5118 5119 5121 16 Event Severity Event Description Error Error building SMBIOS Tables. Probable Cause: SFW failed to build the SMBIOS tables. Recommended Action: If SMBIOS is preventing functionality, reboot. If problem persists contact your HP representative for support. SNMP Trap: hpevtBootSmbiosBuildError - 5098 in HPIFPTRAP.MIB. Error Trap nest limit exceeded. Probable Cause: The trap nesting limit has been exceeded.
Event ID 5123 5124 5125 5127 5130 5131 5132 5133 5136 5137 5138 5139 5140 5141 5142 Event Severity Event Description Warning Expected I/O host bridge is missing . Probable Cause: I/O host bridge failure. An incorrect I/O backplane is installed. Recommended Action: Contact your HP representative to check the I/O host bridge and the I/O backplane. SNMP Trap: hpevtIoCheckLbaMissingErr - 5123 in HPIFPTRAP.MIB. Warning LBA has unexpected number of I/O slots.
Event ID 5143 5144 5145 5146 5147 5148 5149 5150 5152 5155 5156 5157 5158 5159 5160 18 Event Severity Event Description Warning I/O rope reset failed to complete. Probable Cause: I/O CEC failure. Recommended Action: Reboot. If problem persists, contact your HP representative to check the I/O controller. SNMP Trap: hpevtIoRopeResetError - 5143 in HPIFPTRAP.MIB. Warning I/O SBA clear error failed. Probable Cause: I/O chipset failure.
Event ID 5161 5171 5172 5173 5174 5175 5176 5179 5180 5181 5182 5183 5185 5186 Event Severity Event Description Warning Memory ECC normal write/read test failed. Probable Cause: The DIMM that maps to cache line 0 is in a chipspare condition. Recommended Action: Contact HP support SNMP Trap: hpevtMemCacheLine0WrRdFailed - 5161 in HPIFPTRAP.MIB. Warning DIMM loading order error: DIMM deallocated.
Event ID Warning Memory Error Information not cleared. Probable Cause: Software Error or CEC error. Recommended Action: Contact HP support to troubleshoot the problem SNMP Trap: hpevtMemErrClearFail - 5187 in HPIFPTRAP.MIB. Warning Couldn't clear memory error logs. Probable Cause: SFW Error or CEC error. Recommended Action: Contact HP support to troubleshoot the problem SNMP Trap: hpevtMemErrLogFailedToClear - 5189 in HPIFPTRAP.MIB. Warning Memory error clear failed.
Event ID 5218 5219 5237 5238 5244 5245 5248 5250 5252 5253 5255 5256 5257 Event Severity Event Description Warning Memory platform data update failure. Probable Cause: Memory FW was unable to save or restore the original error configuration. Recommended Action: If this is seen, update SFW. SNMP Trap: hpevtMemPlatformInitFailure - 5218 in HPIFPTRAP.MIB. Warning Can't find memory rank entry.
Event ID 5260 5263 5264 5266 5268 5270 5278 5279 5280 5335 5354 5359 5360 5361 22 Event Severity Event Description Warning OS INIT address not registered. Probable Cause: The OS has not registered an OS_INIT vector. Recommended Action: No action is required. The OS has failed to register the vector or has chosen not to. SNMP Trap: hpevtOsInitNotRegistered - 5260 in HPIFPTRAP.MIB. Warning OS MCA address not registered. Probable Cause: The OS has not registered an OS_MCA vector.
Event ID Event Severity Event Description Error The current cell detected incompatible CPUs on another cell. Probable Cause: Mixed CPU types are installed in the same partition. Remove them. SNMP Trap: hpevtPdIncompatibleCpuTypes - 5365 in HPIFPTRAP.MIB. Error Current cell was too slow creating the local rendezvous set. Probable Cause: Cell too slow. Could be bad hardware. Check for other errors and reset. Recommended Action: If assistance is required, contact the HP Support Center.
Event ID 5432 5438 5440 5442 5443 5444 5445 5446 5447 5448 5449 5450 5451 5452 5453 5454 5455 24 Event Severity Event Description Error A Timeout occurred during RI initialization. The CSR is in the data field. The alert level will vary. Probable Cause: Hardware problem such as cable connect error or bad cables. Recommended Action: Correct the hardware problem and re-boot. SNMP Trap: hpevtlotimeout - 5432 in HPIFPTRAP.MIB. Warning SuperIO has been detected in slot.
Event ID Event Severity Event Description Error LBA Fatal Parity error encountered. Probable Cause: An LBA fatal parity error encountered. Recommended Action: Repair/replace the faulty hardware. SNMP Trap: hpevtIoLbaFatalParityErr - 5456 in HPIFPTRAP.MIB. Error LBA Fatal Timeout Error Encountered. Probable Cause: LBA fatal timeout error encountered. Recommended Action: Repair/replace the faulty hardware. SNMP Trap: hpevtIoLbaFatalTimeoutErr - 5457 in HPIFPTRAP.MIB.
Event ID Error The BLOCK requested in NVRAM has the wrong revision. Probable Cause: Clear NVRAM and reset. SNMP Trap: hpevtNvramBlockRevMismatch - 5498 in HPIFPTRAP.MIB. 5499 Warning The requested NVRAM block was not found. Probable Cause: No Action Required. Firmware can allocated space for the block. SNMP Trap: hpevtNvramBlockNotFound - 5499 in HPIFPTRAP.MIB. 5500 Warning The requested NVRAM block is locked. Probable Cause: Retry the operation. SNMP Trap: hpevtNvramBlockLocked - 5500 in HPIFPTRAP.
Event ID Event Severity Event Description 5525 Warning Copying memory test code failed. Probable Cause: Memory test code located in main memory has been corrupted. Recommended Action: Contact HP support personnel to troubleshoot the problem SNMP Trap: hpevtMemTestCodeInPage0Corrupt - 5525 in HPIFPTRAP.MIB. 5527 Error A remote cell is in an unknown state of PD rendezvous. Probable Cause: Reset the PD. SNMP Trap: hpevtRemoteCellStateUnknown - 5527 in HPIFPTRAP.MIB.
Event ID Error This indicates the failure in updating the GNI info of the cell with CLM. Probable Cause: The partition level memory will fail at this point. SNMP Trap: hpevtPdMemUpdateCellGniFailed - 5569 in HPIFPTRAP.MIB. Error This indicates the failure in adjusting the mem info with Minimum ZI req. Probable Cause: This will cause the partition level memory to exit cell interleaving. SNMP Trap: hpevtPdMemAdjustMinZiFailed - 5570 in HPIFPTRAP.MIB. Error Complex Profile A has a checksum error.
Event ID 5597 5598 5599 5600 5601 5602 5603 5604 5605 5606 5607 5617 5618 5619 5621 Event Severity Event Description Error Error Writing BMC first boot token. Probable Cause: Problem accessing the BMC. Recommended Action: AC power cycle or upgrade BMC and System FW. If problem persists contact your HP representative for support. SNMP Trap: hpevtBootErrorWritingFirstBootToken - 5597 in HPIFPTRAP.MIB. Warning Fru Id read error. Probable Cause: Error reading a FRU.
Event ID 5622 5623 5626 5638 5646 5655 5656 5657 5658 5659 5677 5679 30 Event Severity Event Description Error The reporting cell is not configured to be in a PD. Probable Cause: Run parmgr to configure the cell into a PD and reset the PD or add the cell. SNMP Trap: hpevtCellNotInAPd - 5622 in HPIFPTRAP.MIB. Warning DIMM thermal loading order warning. Probable Cause: The current DIMM loading order does not follow the guidelines in the user manual.
Event ID Event Severity Event Description Warning MC_RENDEZVOUS: No MC monarch. Probable Cause: Software is making a SAL_MC_RENDEZVOUS call when it shouldn't. Recommended Action: Just a warning that software or OS is making a call when it shouldn't. SFW will ignore the call when this happen. Need to fix OS or software to not make the SAL_MC_RENDEZVOUS when there is no monarch processor chosen. SNMP Trap: hpevtMcRendezNoMonarch - 5682 in HPIFPTRAP.MIB. Warning MC_RENDEZVOUS: No wakeup registered.
Event ID 5712 5713 5714 5715 5717 5718 5719 5720 5721 5722 5723 5724 5725 5726 32 Event Severity Event Description Warning EFI internal error detected resulting in execution of ASSERT macro. Probable Cause: The cause is unknown. Recommended Action: Look at previous events and ASCII information in this event for more information. If problem persists, contact HP support to troubleshoot the problem. SNMP Trap: hpevtEfiAssertError - 5712 in HPIFPTRAP.MIB.
Event ID 5728 5729 5730 5731 5732 5733 5734 5735 5737 5738 5740 5741 5742 5743 Event Severity Event Description Error There was an error creating or initializing the FPGA node in firmware. Probable Cause: Unable to properly initialize a system firmware node. Recommended Action: Check for other errors in the system first. Invalidate NVM and retry to boot. Get the latest firmware release. SNMP Trap: hpevtFpgaNodeInitError - 5728 in HPIFPTRAP.MIB.
Event ID 5744 5745 5746 5747 5749 5750 5751 5752 5753 5755 5756 5757 5758 5760 34 Event Severity Event Description Warning Prototype CPU installed. Probable Cause: A Prototype CPU is installed. Recommended Action: Replace CPU with a production CPU. SNMP Trap: hpevtBootProtoTypeCpuInstalled - 5744 in HPIFPTRAP.MIB. Warning final boot rendezvous monarch watchdog timeout. Probable Cause: A watchdog timer has expired and determined that a monarch is dead.
Event ID Event Severity Event Description Error A crossbar port is unexpectedly not present. Probable Cause: An XBC is indicating a port failure. Recommended Action: Validate all of the cells connectivity to the PD Check the XBC chips seating reset the system replace either cells/system backplane SNMP Trap: hpevtXbcPortPresenceError - 5762 in HPIFPTRAP.MIB. Error A crossbar port unexpectedly has its HW_LINK_OK bit not set. Probable Cause: An XBC is indicating a port failure.
Event ID 5779 5784 5785 5786 5787 5788 5790 5791 5793 5794 5795 5796 5797 5798 36 Event Severity Event Description Warning Memory DIMM pair mismatch. Probable Cause: The user installed a mismatched pair of DIMMs in the same rank (i.e. the DIMMs are different size or DRAM width). Recommended Action: Install memory ranks in pairs of DIMMs that are the same size and DRAM width. SNMP Trap: hpevtMemDimmPairMismatch - 5779 in HPIFPTRAP.MIB. Error EFI unable to initialize internal library.
Event ID Event Severity Event Description 5799 Error A XBC port was unexpectedly found to be landmined. Probable Cause: No action required. SNMP Trap: hpevtXbcPortLandmined - 5799 in HPIFPTRAP.MIB. Error CPUs running at different speeds were detected during rendezvous. Probable Cause: Reconfigure the PD so that all cells have processors running at the same speed. SNMP Trap: hpevtPdIncompatibleCpuSpeeds - 5800 in HPIFPTRAP.MIB.
Event ID Warning Setting processor response timeout failed. Probable Cause: A PAL call made by SFW has failed. Recommended Action: Reboot if necessary, if problem persists contact your HP representative for support. SNMP Trap: hpevtSettingProcTimeoutFail - 5827 in HPIFPTRAP.MIB. Warning Unable to validate blank password during EFI security initialization. Probable Cause: BMC failed. Recommended Action: Reset the BMC. Update BMC FW. Contact your HP representative to check the BMC.
Event ID 6795 7652 7653 7655 7657 7658 7660 7661 7663 7664 7666 7667 7669 Event Severity Event Description Warning An invalid XBC to XBC port was found. Probable Cause: Loss of Lockstep. Recommended Action: Reset SNMP Trap: hpevtFabricInvalidXbc2XbcPort - 6795 in HPIFPTRAP.MIB. Warning Could not get neighbor information. Probable Cause: Defective XBC link Defective XBC.
Event ID 7671 7673 7674 7684 7685 7686 7690 7718 7732 7733 7734 40 Event Severity Event Description Error Attempted an XBC SM4 takeover and timed out trying to unlock the SM4. Probable Cause: Cannot takeover an XBC semaphore that has been held for a long time. Recommended Action: Try forcing firmware to reroute the fabric by cycling 48V power on the cabinets. Look for other fabric chassis codes that explain why the current owner of the SM4 was unable to release it.
Event ID 7758 7760 7767 7771 7773 7774 7781 7782 7783 Event Severity Event Description Error Copy of complex profile on sub and cells don't match. Probable Cause: MP NVRAM was erased by removing MP from system without setting 'NVRAM SAVE' switch to on. MP was replaced with cabinet's AC Breakers 'off'. Either of first two causes and replacing or installing a cell board with cabinet's AC Breakers 'off'. Recommended Action: Remove cell board causing problem.
Event ID 7784 7786 7791 7793 7795 7796 7798 7799 7803 7806 7822 7823 42 Event Severity Event Description Error No Cabinet Start, Insufficient IO Fans. Probable Cause: The number of IO fans required is a hard number. It is not dependent upon the number of entities installed in a Cabinet. The Utilities Subsystem is not allowing the cabinet to power up due to an insufficient number of installed IO fans.
Event ID 7824 7825 7827 7828 7829 7836 7842 7845 7846 7849 7855 Event Severity Event Description Warning The BPSs for the cabinet are illegally configured. Data Byte 3 = PDCA number. Probable Cause: The BPS are installed in an illegal configuration. Recommended Action: Re-configure the BPS in a manner consistent with the explanation in the Problem Description statement SNMP Trap: hpevtIllegalBpsCfgOrPhaseFlt - 7824 in HPIFPTRAP.MIB.
Event ID 7856 7858 7863 7864 7865 7866 7867 7871 7873 44 Event Severity Event Description Error Invalid checksum from EEPROM. Probable Cause: Problem with I2C bus. Recommended Action: If every entity with a FRUID logs an error, the problem is probably with the CLU portion of the Utilities Board. Replace the Utilities Board following the Utilities Board Remove and Replace Procedures.
Event ID 7874 7875 7877 7878 7879 7880 7891 7892 7893 7894 7895 Event Severity Event Description Warning Failure to read data from a UGUY FRUID EEPROM. Probable Cause: Attempted access to read the UGUY FRUID EEPROM failed. Recommended Action: If there is only one FRUID that can't be read, replace that FRU as soon as possible. If there are a lot of log entries for different FRUs, suspect the Utilities Board or the Utilities cable to those FRUs.
Event ID Error System FW and the PDHC have incompatible shared memory interface revisions. Probable Cause: (Probable) Either System firmware or PDHC Firmware on the named cell was upgraded to a new major revision number and not the other. The major numbers must match when checked by the PDHC or else the cell will not be allowed to boot. Recommended Action: Use FWUU (Firmware Update Utility) to check the revision numbers of PDHC and PDC Firmware on the cell(s) called out in the event log.
Event ID 7974 7975 8009 8010 8127 8128 8130 8131 8132 8133 8134 8135 8136 Event Severity Event Description Error Firmware encountered an error in processing the partition variables. Probable Cause: Either the GSP was not present or there was a resource problem storing the variable. There should be other clues in the event id log to indicate which is the case. Restore the GSP. SNMP Trap: hpevtPartitionVariableError - 7974 in HPIFPTRAP.MIB. Error A non-critical cell power fault has occurred.
Event ID 8137 8138 8139 8140 8141 8143 8147 8149 8151 8153 48 Event Severity Event Description Error Cell boot has been disabled due to a failure setting the frequency registers. Probable Cause: Invalid data programmed in the Cell's FRU EEPROM or a CPU module's Scratch/FRU EEPROM. Recommended Action: If in manufacturing, program correct data in partition specific field of the Cell or CPU Module's FRU EEPROM. Otherwise, contact HP support personnel to troubleshoot the problem.
Event ID 8154 8156 8159 8184 8186 8187 8188 8189 8190 8194 8195 8198 8199 8200 8202 Event Severity Event Description Warning EFI unable to read initial debug level from the BMC. Probable Cause: BMC not functioning properly. Recommended Action: Reset the BMC. Contact your HP representative to check the BMC. SNMP Trap: hpevtEfiDebugLevelTokenErr - 8154 in HPIFPTRAP.MIB. Error A XBC port was unexpectedly found to not be landmined. Probable Cause: An XBC is indicating a port failure.
Event ID Warning Testing of correctable errors injected from the CC has failed. Probable Cause: Either the CC failed to inject the errors, the XBC failed to detect them, or PDC could not access the XBC CSR. Recommended Action: Check results from other cells connected to the same XBC. Check CC, Check XBC, Contact HP Support Personnel. SNMP Trap: hpevtFabricLinkCorErrTestFailure - 8205 in HPIFPTRAP.MIB. Error A cabinet has been configured using an invalid cabinet number.
Event ID 8263 8264 8265 8267 8269 8271 8643 8645 8646 8647 8648 8652 Event Severity Event Description Warning Partition attempted to OLA a cell that was not fully ready for the operation. Probable Cause: OLA cell hung during its part of the OLA process. Consult chassis codes from the OLA cell to determine what happened. A secondary problem here is that the root cell attempted to OLA a cell that could not have sent the Ready to OLA command (since it hung).
Event ID Event Severity Event Description 8676 Error Error writing the XIN init disable register. Probable Cause: Check XBC, CC, backplane SNMP Trap: hpevtFabricXinInitWriteErr - 8676 in HPIFPTRAP.MIB. 8677 Error Error reading the XIN init state register. Probable Cause: Check XBC, CC, backplane SNMP Trap: hpevtFabricXinInitReadErr - 8677 in HPIFPTRAP.MIB. Error intermittent failure while retrying the CC to XBC link init.
Event ID Event Severity Event Description Warning There was an error initializing the LBA. Probable Cause: The LBA component initialization routine failed. Recommended Action: This is an internal system firmware error. Update system firmware or contact a system firmware representative. SNMP Trap: hpevtIodiscLbaInitnodeError - 8715 in HPIFPTRAP.MIB. Error There was an error querying the LBA width. Probable Cause: Error while writing the LBA phase data.
Event ID Warning The Dillon IPR is not cleared after a MAX_RD_CLR_IPR_TRIES on a cell. Probable Cause: The PDH FPGA IPR is not cleared after a MAX_RD_CLR_IPR_TRIES on a cell. Recommended Action: Contact HP Support personnel to troubleshoot the problem. SNMP Trap: hpevtPdhIprNotClearedOnCell - 8761 in HPIFPTRAP.MIB. Warning Indicated the Dillon IPR is not cleared after a number of PDC attempts. Probable Cause: PDH FPGA IPR is not cleared after a number of PDC attempts.
Event ID Event Severity Event Description Warning The bulk specified is warning of a potential thermal problem. Probable Cause: The bulk power supply is warning of an over temperature condition SNMP Trap: hpevtBpsWarnOt - 8818 in HPIFPTRAP.MIB. Error Malloc failed while trying to process and ERM. Probable Cause: Heap space is completely used or corrupt. Contact Product Engineering. SNMP Trap: hpevtErmOutOfHeap - 8819 in HPIFPTRAP.MIB.
Event ID Warning This means that the registry sanity check failed during MCA error handling. Probable Cause: The cells will independently log errors and reset. SNMP Trap: hpevtMcRegistryCheckFailed - 8860 in HPIFPTRAP.MIB. Warning This means that MCA occurred while OS_MCA was performing error recovery. Probable Cause: The cells will log information and reset. SNMP Trap: hpevtMcDuringOsMca - 8861 in HPIFPTRAP.MIB. Warning One of the BT errors occurred that results in abandoning memory dump.
Event ID 8926 8930 8931 8936 8939 8940 8941 8942 8954 8959 8960 8962 8964 8965 Event Severity Event Description Warning Failed disabling the XIN link for a single cell model. Probable Cause: Fabric Access Error. Recommended Action: Contact HP Support personnel to analyze the fabric. SNMP Trap: hpevtFabricInitCcLinkDisableErr - 8926 in HPIFPTRAP.MIB. Error Error while getting the XBC Semaphore.
Event ID Error Couldn't determine the complex fabric topology. Probable Cause: Fabric Access Error. Couldn't write this XBC. Recommended Action: Contact HP Support personnel to analyze the fabric. SNMP Trap: hpevtFabricRtgCompleteTopologyErr - 8966 in HPIFPTRAP.MIB. Warning Error checking a cell to cell link during traversability tests. Probable Cause: Probably an error reading the XIN. Look for additional descriptive chassis codes.
Event ID 8983 8984 Event Severity Event Description Error A fabric walk failed while updating the cell state. Probable Cause: Look for adjacent chassis codes to determine the cause of FabricWalk failure. Check the backplane and fabric connectivity. Contact the HP Support Personnel for further troubleshooting. SNMP Trap: hpevtBootSetCellStateFabricFailure - 8983 in HPIFPTRAP.MIB. Error Could not reset the cell due to failure updating cell state.
Event ID Event Severity Event Description 9043 Warning A reset for reconfiguration will be performed soon on the cell. Probable Cause: An error during cell initialization occurred and the cell will not be able to join the partition. Look for other errors in the event log that articulate the exact problem. SNMP Trap: hpevtReconfigResetScheduled - 9043 in HPIFPTRAP.MIB. 9045 Warning The Partition Profile specifies the wrong architecture type.
Event ID Event Severity Event Description 9371 Warning Cell about to be halted because CPU couldn't change its CPU FP (PST) state. Probable Cause: Hardware problem with the cell (like PDH memory) or the CC or CPU. Recommended Action: Contact HP support to troubleshoot or replace the cell board. SNMP Trap: hpevtBootMoveSlavesFpSetErr - 9371 in HPIFPTRAP.MIB. 9372 Error Partition about to be reset because PDC couldn't get address to a structure.
Event ID Event Severity Event Description 9390 Error MPON failed to release. Probable Cause: A hardware fault has occurred. Recommended Action: Contact HP Support personnel to troubleshoot the Cell Board, Cell Power Board and PDH Daughtercard. SNMP Trap: hpevtPdhcMponFailed 9390 in HPIFPTRAP.MIB. 9391 Error Dillon failed to reset. Probable Cause: Hardware failure. Recommended Action: Fix the hardware, pdh riser or cell. SNMP Trap: hpevtPdhcDillonResetFailed - 9391 in HPIFPTRAP.MIB.
Event ID Event Severity Event Description 9438 Warning PDHC has detected the PDH battery low warning. Probable Cause: PDH battery power is low. Recommended Action: Replaced the PDH battery. SNMP Trap: hpevtPdhBatteryPowerLow - 9438 in HPIFPTRAP.MIB. 9440 Error FW will not handoff to the OS_MCA handler for this MCA event. Probable Cause: The error logs should be retrieved from the EFI shell prompt. SNMP Trap: hpevtNoHandoffToOsMca - 9440 in HPIFPTRAP.MIB.
Event ID Event Severity Event Description 9471 Error Failed to read the XBC CSR that contains the number of failed links. Probable Cause: Fabric Access Failure. Recommended Action: Contact HP Support personnel to check the XBC, Backplane, CC, look for additional chassis codes to describe the problem. SNMP Trap: hpevtFabricIncFailedLinksRdError - 9471 in HPIFPTRAP.MIB. 9472 Error Failed to write the XBC CSR that contains the number of failed links. Probable Cause: Fabric Access Failure.
Event ID Event Severity Event Description 9486 Error The system firmware had an error with the structured error handling mechanism. Probable Cause: Either there is an error in the system firmware or the system firmware has exhausted all resources. Recommended Action: Invalidate NVM or check for newer version of system firmware. SNMP Trap: hpevtIoErrengineError - 9486 in HPIFPTRAP.MIB. 9487 Error Not enough malloc resources for I/O structure error handling.
Event ID Event Severity Event Description 9653 Warning Windows: Server Agents Management data not accessible, locked property. Probable Cause: The installed management software has detected an unstable state of the underlying IPMI (Intelligent Platform Management Interface) subsystem and has disabled all management information from being shown by any manageability applications. The management information will become available automatically as soon as the IPMI subsystem has stabilized.
Event ID Event Severity Event Description 9682 Warning Firmware unable to relocate VGA BIOS. Probable Cause: Most likely there is a permanent memory error in the VGA BIOS region (physical address 0xc0000 - 0xdffff). Recommended Action: Replace the DIMM causing the permanent memory error in the VGA BIOS region. The PDT reports which DIMM is causing errors in the physical address range 0xc0000 - 0xdffff. SNMP Trap: hpevtVgaBiosRelocFail - 9682 in HPIFPTRAP.MIB.
Event ID Event Severity Event Description 9710 Warning The core cell selected is not in the rendezvoused partition. Probable Cause: Configuration error, main backplane failure; the intended core cell failed during boot. Recommended Action: check partition configuration, check for failed cells, check for additional chassis codes indicating more failure detail. SNMP Trap: hpevtBootFindCoreCellNotInRendez - 9710 in HPIFPTRAP.MIB. 9711 Warning The local cell is not viable.
Event ID Event Severity Event Description 9751 Error Windows: Predictive Failure in Memory (Critical). Probable Cause: You will receive this message if the system is correcting a lot of ECC single bit errors. It may mean that the module is about to fail, or environmental conditions in the server are causing more errors than usual. This event message will be generated for one of the following conditions 1500 single-bit errors on the same address in a 72 hour time period.
Event ID Event Severity Event Description 9780 Warning Failed to read the XBC CSR Error Status register. Probable Cause: Fabric Access Failure. Likely hardware problem. Look for additional chassis codes to further isolate the error. SNMP Trap: hpevtFabricErrsCsrLogClrRdSlicesErr - 9780 in HPIFPTRAP.MIB. 9781 Warning Failed to copy the XBC CSR Error Symbol01 Block. Probable Cause: Fabric Access Failure; Possibly an invalid destination address.
Event ID Event Severity Event Description 9867 Warning CPU deconfigured during FSB interface initialization. Probable Cause: internal error. Recommended Action: the CPU will be deconfigured. If the error persists after a powercycle, contact HP Support. SNMP Trap: hpevtDcnfgFsbInit - 9867 in HPIFPTRAP.MIB. 9868 Warning CPU deconfigured due to error obtaining parameters from PAL. Probable Cause: internal error. Recommended Action: the CPU will be deconfigured.
Event ID Event Severity Event Description 10060 Warning The left cell latch is open. SNMP Trap: hpevtCellLatchOpen - 10060 in HPIFPTRAP.MIB. 10061 Warning Right ejector latch is open. Probable Cause: The right ejector latch is open. Recommended Action: Close the right ejector latch on the specified cell. SNMP Trap: hpevtDcnfgRightCellLatch - 10061 in HPIFPTRAP.MIB. 10062 Warning The optical emitters on the cell latch sensors are not functioning. Probable Cause: There is a hardware failure.
Event ID Event Severity Event Description 10209 Warning fabric API is about to open the a link going out of the local cell. Probable Cause: An error prevented the use of a fabric link. Recommended Action: Collect IPMI event logs for more information regarding the failure. Contact your HP Support Representative to investigate the fabric subsystem. SNMP Trap: hpevtAPIopenLnkLocCell - 10209 in HPIFPTRAP.MIB. 10272 Error An Arches fabric CSR read was unsuccessful because of a timeout.
Event ID Event Severity Event Description 10378 Warning XBC port with an unexpected neighbor chip type. Data field: (expected chip type) | (actual chip type 16) | (xbcNum 32) |(portNum 48). Probable Cause: System firmware noticed a discrepancy from the expected topology of the system. Recommended Action: Capture IPMI event logs, look for additional errors. Contact your HP Support Representative to analyze the fabric SNMP Trap: hpevtXBCPortUnexpctNghbrChip - 10378 in HPIFPTRAP.MIB.
Event ID Event Severity Event Description 10389 Warning Error reading Skyline ALREC_ALB_ID CSR. Data field: (Skyline port) | (Cell number 56). Probable Cause: System firmware was unable to read a fabric hardware register. Recommended Action: Capture IPMI event logs, look for additional errors. Contact your HP Support Representative to analyze the fabric SNMP Trap: hpevtErrRdAlrecAlbIdCsr - 10389 in HPIFPTRAP.MIB. 10390 Warning A circular route was found while testing XBC CSR traffic traversability.
Event ID Event Severity Event Description 10402 Warning Arches Fabric Traversability code unexpectedly found the local cell link not connected. Data field: linkState (0 = connected, 1 = link pending, 2 = not connected, -1 = error). Probable Cause: A previously healthy link was found to have fatal errors. Recommended Action: Capture IPMI event logs, look for additional errors. Contact your HP Support Representative to analyze the fabric SNMP Trap: hpevtArchFabFndLocCelLnkNotConn - 10402 in HPIFPTRAP.
Event ID Event Severity Event Description 10414 Warning In SetupNCTable, a write to the GLOBAL_LINK_SEL_NONCOH CSR failed. Data field: (data written to CSR) | (actual CSR data read 32). Probable Cause: System firmware was unable to write a fabric hardware register. Recommended Action: Capture IPMI event logs, look for additional errors. Contact your HP Support Representative to analyze the fabric SNMP Trap: hpevtNctTblWrtGlobLnkSelNonCohFail - 10414 in HPIFPTRAP.MIB.
Event ID Event Severity Event Description 10481 Warning System Firmware was unable to access the configured set stored in the complex profile. Probable Cause: SFW was unable to access the configured set stored in the complex profile. Recommended Action: Collect IPMI events and contact your HP Support Representative. SNMP Trap: hpevtSysFwUnAccesComplxProf - 10481 in HPIFPTRAP.MIB. 10482 Warning System Firmware detected an error during Fabric Init.
Event ID Event Severity Event Description 10523 Warning Failure to get the XBC Global Semaphore address. Probable Cause: Failed to get a fabric address. Recommended Action: Look for additional IPMI event logs. Contact your HP Support Representative to analyze the fabric. SNMP Trap: hpevtFailGetXbcGlobSemphrAddr - 10523 in HPIFPTRAP.MIB. 10524 Warning Failed to write the XBC Global Semaphore. Probable Cause: write to XBC failed.
Event ID Event Severity Event Description 10566 Warning Error while routing the remote side of a route. Probable Cause: System Firmware was unable to route the crossbar fabric. Recommended Action: Collect IPMI Event logs. Contact your HP Support Representative to troubleshoot the fabric and/or backplane subsystem. SNMP Trap: hpevtErrRoutRemtside - 10566 in HPIFPTRAP.MIB. 10567 Warning Error getting address while routing the remote XBC. Probable Cause: Failed to get a fabric address.
Event ID Event Severity Event Description 10622 Warning Unexpected return from an Arches Fabric vertex module function while copying a cell's graph. Data field: return value from vertex module function. Probable Cause: Internal firmware error or data corruption. Recommended Action: Capture IPMI event logs, look for additional errors. Contact your HP Support Representative to analyze the fabric SNMP Trap: hpevtUnexpctRetVertxModCopCelGrph - 10622 in HPIFPTRAP.MIB.
Event ID Event Severity Event Description 10706 Error An internal firmware inconsistency exists or the server exhausted its internal resources and is unable to create an fPars EFI ownership variable for a CPU device in the partition. Either of these conditions is fatal. Probable Cause: NVRAM corruption of fPars specific database. Recommended Action: Restore NVRAM to factory defaults. Reset server and reconfigure soft partitions. SNMP Trap: hpevtFWInconsistExist 10706 in HPIFPTRAP.MIB.
Event ID Event Severity Event Description 10822 Warning Over-temperature condition detected on a processor. Probable Cause: The processor temperature is above the operating range. The processor's performance is throttled by the firmware to reduce the temperature. Recommended Action: The firmware has already taken necessary action. Once the temperature comes down, the firmware will restore the processor's performance to normal SNMP Trap: hpevtPFMOverTempProc - 10822 in HPIFPTRAP.MIB.
Event ID Event Severity Event Description 10833 Warning Firmware error setting the NVRAM value of preferred-bsp for the vPars monitor. The partition will boot using the PD monarch, but the value of preferred-bsp may not match this CPU. Probable Cause: Firmware could not store to the NVRAM holding the EFI preferred-bsp variable. Recommended Action: Reset the server, restore factory default NVRAM and reconfigure soft partitions. SNMP Trap: hpevtFWErrSetNvramVal - 10833 in HPIFPTRAP.MIB.
Event ID Event Severity Event Description 10941 Warning Too many edges were encountered during a procedure call. Data Field: link count. Probable Cause: There was a problem while collecting a list of fabric link info. Recommended Action: Look for additional IPMI event logs. Contact your HP Support Representative to analyze the fabric. SNMP Trap: hpevtManyEdgEncntProcCall 10941 in HPIFPTRAP.MIB. 10943 Warning Failed to get an address during a procedure call. Data Field: return status.
Event ID Event Severity Event Description 11040 Warning An error was encountered while routing the fabric. This error prevents an appropriate route from being selected. Data Field: Destination Cell 56 | XBC Port 44 | XBC # 32 | return status. Probable Cause: An error occurred while routing the fabric. Recommended Action: Contact your HP support representative to inspect the fabric and system firmware. SNMP Trap: hpevtErrEncntRoutFabPrvntRoutSel - 11040 in HPIFPTRAP.MIB.
Event ID Event Severity Event Description 11468 Error Clock fault for clocks supplied from the Redundant Clock Source (RCS) board to the system backplane. RCS board is no longer providing clocks to the backplane. The data field contains the physical location of the RCS. Probable Cause: RCS assembly has reported a fault. Recommended Action: Check RCS assembly. SNMP Trap: hpevtRcsNoProvClkBckPln - 11468 in HPIFPTRAP.MIB.
Event ID Event Severity Event Description 11496 Warning Failure writing IO backplane LPM. Probable Cause: IO Backplane LPM is not accessible over i2c. Recommended Action: Check power status of IO backplane. SNMP Trap: hpevtFailWrtIOBckPlnLpm - 11496 in HPIFPTRAP.MIB. 11515 Warning The system software violated one of the 'well-behavedness' rules of soft partitions and tried to call a firmware procedure within the firmware instance of a sibling.
Event ID Event Severity Event Description 11568 Error IO Backplane -12V power fault. Probable Cause: One of the -12v VRM's is reporting a fault, one failure and power state is N, after two power state will be N-. Recommended Action: Check IO backplane power board faulted VRM is give by PS command. SNMP Trap: hpevtIOBckPlnNeg12VFail - 11568 in HPIFPTRAP.MIB. 11569 Error IO Backplane +12V power fault. Probable Cause: One of the +12v VRM's is reporting a fault.
Event ID Event Severity Event Description 11586 Warning An unexpected error occurred while setting up the Non-Coherent or Coherent tables after an OLA. Data field: return value from SetupNCTable() or SetupCohTable(). Probable Cause: An error occurred while routing the fabric. Recommended Action: Collect IPMI event logs, and contact your HP support representative to inspect the fabric and system firmware. SNMP Trap: hpevtRetValNctCohTbl - 11586 in HPIFPTRAP.MIB.
Event ID Event Severity Event Description 11703 Error The configured CPU generation is not supported. Probable Cause: The configuration contains an unsupported CPU generation. Recommended Action: Modify the configuration to use a supported CPU generation SNMP Trap: hpevtCPUConfigNotSupprt - 11703 in HPIFPTRAP.MIB. 11705 Error An ISA UART was created without a data structure. A PCI UART structure exists.
Event ID Event Severity Event Description 11723 Error Driver was unable to build map tables. Probable Cause: Insufficient resources or PMAN kernel memory too fragmented. Recommended Action: Add memory or reboot SNMP Trap: hpevtDrvUnableBldMapTbl - 11723 in HPIFPTRAP.MIB. 11724 Error Reboot failed. The virtual machine will exit. Probable Cause: The virtual machine was unable to restart. The next event contains the Unix error.
Event ID Event Severity Event Description 11851 Warning Firmware had an unexpected error while setting up links. Data field: vType1 [63:56] | vPort1 [55:48] | vId1 [47:32] | vType2 [31:24] | vPort2 [23:16] | vId2 [15:0]. Probable Cause: An error occurred while routing the fabric, possible data corruption or firmware error. Recommended Action: Collect IPMI event logs, and contact your HP support representative to inspect the fabric and system firmware.
Event ID Event Severity Event Description 11967 Error Cell on-line add/delete in FPARs mode failed to get the FPARs semaphore. Probable Cause: Cell on line add/delete in FPARs mode failed to get the FPARs semaphore. Recommended Action: Do not use cell on line add/delete in FPARs mode. SNMP Trap: hpevtFailGetFPARsSemphr - 11967 in HPIFPTRAP.MIB. 11968 Error More than one processor from an FPAR called into cell on-line add/delete.
Event ID Event Severity Event Description 12025 Warning An error encountered while retrieving the expected neighbor fabric chip for distributing traffic over crossbar links. Probable Cause: Unexpected error retrieving information from the fabric graph. Recommended Action: Collect IPMI event logs and contact your HP Support Representative to investigate the fabric system firmware subsystem SNMP Trap: hpevtErrRetrvCrssbarLnk - 12025 in HPIFPTRAP.MIB.
Event ID Event Severity Event Description 12109 Warning An error occurred while retrieving the crossbar chip number. Probable Cause: System firmware had difficulty determining the crossbar number from the graph data structure. Recommended Action: Capture IPMI event logs, look for additional errors. Contact your HP Support Representative to analyze the fabric SNMP Trap: hpevtErrRetrvCrssbarChipNmbr - 12109 in HPIFPTRAP.MIB.
Event ID Event Severity Event Description 12135 Warning Duplicate DIMM serial numbers have been detected. Data field gives physical location of DIMM. Check for other events specifying other DIMMs with same serial number. Probable Cause: Multiple DIMMs have the same serial number. Recommended Action: Replace DIMMs with duplicate serial numbers. Ensure new DIMMs have unique serial numbers. SNMP Trap: hpevtDupDimNumDetect - 12135 in HPIFPTRAP.MIB.
Event ID Event Severity Event Description 12161 Warning The operating system has recovered from a PCI error. Probable Cause: If the data word is not 0x0000000400000000, then the problem is most likely with the PCI card. If the value of the data word is 0x0000000400000000, then check event log with keyword PCI_ERROR_STATUS. If PCI_ERROR_STATUS > 1, then the problem is in the connection between System Bus Adapter and Lower Bus Adapter.
Event ID Event Severity Event Description 12195 Error This is an internal SW error. See Cause/Action. Probable Cause: A CPU has tried to acquired the same semaphore twice which resulted in a deadlock. This is an internal SFW error and is not recoverable. Recommended Action: Collect the entire FPL, SEL, console logs and forward them to the SFW team. Also note all activities around the time of this event. The entire logs must analyzed by the SFW team before further actions can be taken.
Event ID Event Severity Event Description 12228 Warning Over-Temperature or power condition detected for processor. Probable Cause: The processor temperature or power has exceeded normal limits. The Enhanced Thermal Management (ETM) feature of the processor has been employed to reduce the chip power to allow operation within normal limits. If this condition persists, this will have an adverse impact on the performance of this processor.
Event ID Event Severity Event Description 12296 Warning The cell being added has incompatible hardware or firmware revision with the partition. Probable Cause: The cell being added has incompatible hardware or firmware revision with the partition. Recommended Action: Previous events will give a description of the error that led to this event. These need to be corrected before the cell can be added. SNMP Trap: hpevtCellHasIncomptbleHwFW - 12296 in HPIFPTRAP.MIB.
Event ID Event Severity Event Description 12395 Error An unrecoverable processor interrupt occurred while in IPF firmware. The event data is the processor status register. If assistance is required, notify the Call Center and provide them with the console log containing the register dump. Probable Cause: Probable bug in System Firmware, EFI driver, EFI app or OS loader (prior to OS launch). Recommended Action: Provide console log containing register dump to HP Customer Engineer.
Event ID Event Severity Event Description 12557 Warning HP unsupported DIMM(s) has been detected on this partition. Probable Cause: HP PFM service has detected one or more HP unsupported DIMMs on this partition. Recommended Action: Make sure to have HP supported DIMMs installed. SNMP Trap: hpevtUnSupprtDimmInPartition - 12557 in HPIFPTRAP.MIB. 12560 Error OS run-time critical shutdown occurred. Probable Cause: The OS has caused the system to shut down.
Event ID Event Severity Event Description 258 Warning The Foundation Agents service could not register with the Service Control Manager. The data contains the error code. 259 Warning The Foundation Agents service could not set the service status with the Service Control Manager. The data contains the error code. 260 Warning The Foundation Agents service could not create an event object. The data contains the error code.
Event ID Event Severity Event Description 1165 Warning Threshold Agent: Critical Falling Threshold Passed. SNMP MIB Variable %1 has value %2 <= %3. Severity: %5 Description: %6. Refer to the MIB for a definition of the variable. [SNMP TRAP: 10008 in CPQTHRSH.MIB] 1166 Warning Foundation Agent: %1 [SNMP TRAP: 11011 in CPQHOST.MIB] 1167 Warning Cluster Agent: The cluster resource %4 has become degraded. [SNMP TRAP: 15005 in CPQCLUS.
Event ID Event Severity Event Description 1800 Warning Component: Foundation SNMP Agent Error: Unable to read security configuration information. SNMP sets have been disabled. Cause: This can be cause by an invalid or missing configuration or by a corrupt registry. Reinstalling the Management Agents may 1803 Error Component: %4 Error: Unable to load a required library. Cause: This error can be caused by a corrupt or missing file.
Event ID Event Severity Event Description 2354 Warning The Threshold Agent could not create an SNMP session. The data contains the error code. 2356 Warning The Threshold Agent could do thresholding on a non-integer object: "%1". The data contains the error code. 2357 Warning The Threshold Agent could not set the variable because it is unsupported. The data contains the error code. 2358 Warning The Threshold Agent could not set the variable because the value is invalid or out of range.
Event ID Event Severity Event Description 4358 Warning The External Status MIB Agent could not create a necessary event. The data contains the error code. 4359 Warning The External Status MIB Agent could not set an event. The data contains the error code. 4360 Warning The External Status MIB Agent could not create its main thread of execution. The data contains the error code. 4361 Warning The External Status MIB Agent main thread did not terminate properly. The data contains the error code.
HpInsightMgmtAgts (Insight Management Agent) Events Event ID Event Severity Event Description 5 Error [Server Agents] IPMI failure: could not obtain the system object. The error code is %d. 5 Error [Server Agents] IPMI failure: could not obtain the system object. 5 Error [Server Agents] IPMI failure: could not obtain IPMI Controller. 5 Error [Server Agents] IPMI failure: could not get device ID. 5 Error [Server Agents] IPMI failure: could not obtain IPMI base controller.
Event ID Event Severity Event Description 107 Error %1 Failed to initialize API: %2. %3 %1 - "[component name]" %2 - "EventApi" %3 "See log file for details." 107 Error %1 Failed to initialize API: %2. %3 %1 - "[component name]" %2 - "EventApi" %3 "See log file for details." 108 Warning %1 An exception occurred: %2. %3 %1 - "[component name]" %2 - "error code = error code" %3 - "See log file for details." 111 Error %1 The %2 service was finished unexpectedly.
Event ID Event Severity Event Description 1004 Error The IPMI device driver attempted to communicate with the IPMI BMC device during normal operation. However the communication failed due to a timeout. You can try increasing the timeouts associated with the IPMI device driver located in the registry at HKLM\SYSTEM\CurrentControlSet\Control\IPMI\CommandWaitTimeoutPeriod, between 5000000 to 10000000 usec, the default is 5000000 usec.
Event ID Event Severity Event Description 2 Informational The Predictive Failure Monitor sub-service has stopped 3 Error PFM cannot initialize WMI interface. Please check WMI service status. NIC Agent Events 112 Event ID Event Severity Event Description 256 Warning The NIC Agent detected an error. The insertion string is: %1. The data contain the error code. 257 Warning Component: NIC Agent Error: Unable to allocate memory. Cause: This indicates a low memory condition.
Event ID Event Severity Event Description 277 Informational The NIC Agent version %1 has started. 280 Warning The NIC Agent service could not start any agents successfully. 298 Error Component: NIC Agent Error: A Fatal error occurred during Virus Throttle WMI event processing. Virus Throttle related traps will not be sent. Cause: WMI service is probably not running. Starting WMI service or NIC agent might solve this problem.
Server Agent Events Event ID 256 Warning The Server Agents service detected an error. The insertion string is: %1. The data contains the error code. 257 Warning The Server Agents service could not allocate memory. The data contains the error code. 258 Warning The Server Agents service could not register with the Service Control Manager. The data contains the error code. 259 Warning The Server Agents service could not set the service status with the Service Control Manager.
Event ID Event Severity Event Description 1540 Error Component: System Information Agent%n Error: Unable to read from the registry.%n Cause: This error can be caused by a corrupt registry or a low memory condition. Rebooting the server may correct this error. 1541 Error Debug: The System Information Agent experienced an error while trying to create events for Health monitor thread. Error information follows. 1542 Error Debug: The System Information Agent was unable to start a monitor thread.
Event ID Event Severity Event Description Warning Debug: The Server SNMP Agent was unable to forward an SNMP trap to the Remote Insight Board trap due to a processing error. The data contains the error code. 1806 Warning Component: Server SNMP Agent%n Error: The Server Agent service is not running.%n Cause: The Server SNMP Agent has determined that the Server Agent service is not running. Stop the SNMP service and restart the Server Agents service.
Event ID Event Severity Event Description 1062 Error Drive Array Logical Drive Status Change. Logical drive number %5 on the array controller in slot %4 has a new status of %2.%n(Logical Drive status values: 1=other, 2=ok, 3=failed, 4=unconfigured, 5=recovering, 6=readyForRebuild, 7=rebuilding, 8=wrongDrive, 9=badConnect, 10=overheating, 11=shutdown, 12=expanding, 13=notAvailable, 14=queuedForExpansion)%n [SNMP TRAP: 3008 in CPQIDA.MIB] 1063 Error Drive Array Spare Drive Status Change.
Event ID Event Severity Event Description 1201 Warning Drive Array Spare Drive Status Change. The spare drive in %4, port %5, bay %6 has a new status of %2.%n(Spare status values: 1=other, 2=invalid, 3=failed, 4=inactive, 5=building, 6=active)%n [SNMP TRAP: 3035 in CPQIDA.MIB] 1202 Warning Drive Array Physical Drive Status Change. The physical drive in %4, port %5, bay %6 with serial number "%7", has a new status of %2.
Event ID Event Severity Event Description 1148 Error External Array Accelerator Status Change. The array accelerator board attached to the external controller in I/O slot %5 of array "%4" has a new status of %6.%n(Accelerator status values: 1=other, 2=notConfigured, 3=enabled, 4=tmpDisabled, 5=permDisabled)%n [SNMP TRAP: 16017 in CPQFCA.MIB] 1149 Error External Array Accelerator Bad Data.
Event ID Event Severity Event Description 1198 Warning External Tape Library Door Status Change. The tape library at location "%4", has a new door status of %7.%n(Library door status values: 1=other, 2=notSupported, 3=closed, 4=open)%n [SNMP TRAP: 16027 in CPQFCA.MIB] 1215 Warning Fibre Channel Controller Status Change. The Fibre Channel Controller in %4 has a new status of %5.
Event ID Event Severity Event Description 3594 Warning The IDE Agent could not open a mutex. The data contains the error code. 3595 Warning The IDE Agent could not create its main thread of execution. The data contains the error code. 3596 Warning The IDE Agent main thread did not terminate properly. The data contains the error code. 3597 Warning The IDE Agent got an unexpected error code while waiting for an event. The data contains the error code.
Event ID Event Severity Event Description 1070 Error SCSI Physical Drive Status Change.%nThe SCSI physical drive with SCSI target %6 connected to SCSI bus %5 of the controller in slot %4 has a new status of %2.%n(Drive status values: 1=other, 2=ok, 3=failed, 4=notConfigured, 5=badCable, 6=missingWasOk, 7=missingWasFailed, 8=predictiveFailure, 9=missingWasPredictiveFailure, 10=offline, 11=missingWasOffline)%n [SNMP TRAP: 5020 in CPQSCSI.MIB] 1107 Error SCSI Tape Drive Status Change.
Event ID Event Severity Event Description 1280 Warning Error: Unable to allocate memory. Cause: This indicates a low memory condition. Rebooting the system will correct this error. 1281 Warning Error: Could not read from the registry subkey. Cause: This error can be caused by a corrupt registry or a low memory condition. Rebooting the server may correct this error. 1282 Warning Error: Could not write the registry subkey: "%1".
Event ID Event Severity Event Description 267 Warning The Storage Agents service could not start agent "%1". The data contains the error code. 268 Warning The Storage Agents service detected an invalid state for agent "%1". The data contains the state. 269 Warning The Storage Agents service could not stop agent "%1". The data contains the error code. 270 Warning The Storage Agents service could not terminate agent "%1". The data contains the error code.
Event ID Event Severity Event Description 1077 Warning Storage System Temperature Degraded.%nThe %6 %7 storage system connected to SCSI bus %5 of the controller in slot %4 system has a temperature outside the normal operating range.%n [SNMP TRAP: 8010 in CPQSTSYS.MIB] 1078 Informational Storage System Temperature OK.%nThe temperature in the %6 %7 storage system connected to SCSI bus %5 of the controller in slot %4 has returned to the normal operating range.%n [SNMP TRAP: 8011 in CPQSTSYS.
Event ID Event Severity Event Description 1213 Warning Storage System Temperature Status Change.%nThe %6 %7 storage system connected to SCSI bus %5 of the controller in %4 has a new temperature status of %2.%n(Temperature status values: 1=other,2=ok,3=degraded,4=failed,5=notInstalled) %n [SNMP TRAP: 8027 in CPQSTSYS.MIB] 1214 Warning Storage System Fault Tolerant Power Supply Status Change.