Windows Server 2008 R2 on HP Integrity Servers Installation Guide HP Part Number: 5992-5680 Published: November 2010
© Copyright 2011 Hewlett-Packard Development Company, L.P. Legal Notices Confidential computer software. Valid license from HP required for possession, use or copying. Consistent with FAR 12.211 and 12.212, Commercial Computer Software, Computer Software Documentation, and Technical Data for Commercial Items are licensed to the U.S. Government under vendor's standard commercial license. The information contained herein is subject to change without notice.
Table of Contents About This Document.........................................................................................................9 Intended Audience.................................................................................................................................9 New and Changed Information in This Edition.....................................................................................9 Document Organization.....................................................................
Reinstall from a GUI Console...............................................................................................................49 Load the System Image to the Boot Disk.........................................................................................50 Configure after the Initial Boot........................................................................................................51 Activate the OS......................................................................................
C nPartitioning.................................................................................................................81 Quick Start............................................................................................................................................81 Getting to Know nPartitions.................................................................................................................82 Partitioning Continuum..............................................................
Using SMH............................................................................................................................................99 Accessing WebAgents....................................................................................................................100 Navigating SMH............................................................................................................................100 The SMH Home Page..............................................................
List of Figures 1-1 1-2 1-3 2-1 2-2 2-3 2-4 2-5 2-6 2-7 2-8 2-9 2-10 2-11 2-12 2-13 2-14 2-15 2-16 2-17 2-18 2-19 2-20 2-21 2-22 2-23 2-24 2-25 2-26 2-27 3-1 3-2 3-3 3-4 B-1 C-1 C-2 E-1 Headless Console Configurations.................................................................................................19 GUI Console Configuration..........................................................................................................21 PXE/WDS Configuration.......................................
List of Tables 1-1 1-2 1-3 1-4 B-1 8 Installation Matrix.........................................................................................................................15 Location of the COA on Your Server.............................................................................................16 Graphics Support and Server Models...........................................................................................21 EFI Device Mapping Fields...............................................
About This Document This document describes how to install and configure the operating system and HP software on HP Integrity servers running Microsoft® Windows Server™ 2008 R2 Itanium™ Edition. The document publication date and part number indicate the document’s current edition. The publication date changes when a new edition is printed. Minor changes may be made at reprint without changing the publication date. The document part number changes when extensive changes are made.
“SMH and the WBEM Providers” An overview of the WBEM Providers and how to configure System Management (page 99) Homepage (SMH) to administer your system locally or remotely. “Headless Windows Installations” (page 107) An overview of the benefits, concepts, and terminology of headless operating system installation on HP Integrity servers.
— to locate documents by server model number: http://www.hp.com/go/ integrity_servers-docs • Microsoft's Windows Server 2008 R2 support website: http://www.microsoft.com/windowsserver2008/en/us/default.aspx Publishing History The document part number and publication date indicate the document’s current edition. The publication date will change when a new edition is printed. Minor changes may be made at reprint without changing the publication date.
1 Preparing for Installation Installing Microsoft Windows Server 2008 R2 for Itanium-based systems on an HP Integrity server involves preparing the hardware for operating system (OS) installation, loading the OS, and updating the system with the latest OS patches (Microsoft QFEs). This chapter helps you plan the installation based on the server model, the OS edition, the source of the OS media, and your network environment. Subsequent chapters guide you through the installation process.
operating system. HBAs from different vendors rarely support the same maximum I/O packet size. This can create I/O conflicts that cause the system to lock up with a blue screen, a stopcode of 0X000000D1, and a reference to the file elxstor.sys. The solution to this problem is to make sure that all HBAs in the system are manufactured by the same vendor (and therefore have the same maximum I/O packet size). Current HBA vendors include Emulex and Qlogic.
Table 1-1 Installation Matrix Server Model Installation Method Installation Media Non Cell-Based Servers Headless Console Windows Server 2008 R2 OS disc (provided by Microsoft) + HP Smart Setup disc + HP Smart Update disc rx2660 HP Reinstallation disc + HP Smart Setup disc + HP Smart Update disc rx3600 rx6600 GUI Console Windows Server 2008 R2 OS disc (provided by Microsoft) + HP Smart Setup disc + HP Smart Update disc BL860c BL870c HP Reinstallation disc + HP Smart Setup disc + HP Smart Update
NOTE: Table 1-2 shows the location of your primary product key. Another key, the “virtual” key, is also required if you are installing a Windows Server 2008 R2 guest in a virtualized host. Table 1-2 Location of the COA on Your Server 16 Integrity Server Location rx2660 The COA is located on the left side panel, in the middle, as shown. rx3600 The COA is located on the left side panel, as shown. rx6600 The COA is located on the left side panel.
Table 1-2 Location of the COA on Your Server (continued) Integrity Server Location BL860c i2, BL870c i2, and BL890c i2 The COA is located on the back side of the Scalable Blade Links (SBL) label card. Lift the lid open, push the label card to one side so you can grip an edge, remove the card, and flip it over. The COA should be affixed inside the white square. rx2800 i2 The COA is located on the pullout slide on the left side of the front bezel, as shown.
Table 1-2 Location of the COA on Your Server (continued) 18 Integrity Server Location rx8640 The COA is located in the front of the system, at the bottom, near the power supply as shown in the first image. If additional COAs are required, they are located as shown in the second image. Superdome sx2000 The COA is located inside the unit, on the left, in the open space between the cells and the extended I/O cabinet (IOX).
Task 6: Set Up an Installation Method Choose one of the following methods to install the operating system: • Local installation methods: — Headless console — GUI console • Remote installation methods: — Integrated Remote Console (IRC) — Preboot execution environment (PXE) + Windows Deployment Services (WDS), or PXE/WDS If you are installing locally, you must set up your server with a headless or GUI console.
You can configure a headless console by using one of the following: • • • A null modem cable A cat5 LAN cable A Remote Serial Console The first two methods require a terminal emulation application such as HyperTerminal or PuTTY. PuTTY is a free implementation of telnet and SSH for 32-bit Windows and UNIX. PuTTY provides an X terminal. You must use PuTTY version 0.59 or higher, available from the PuTTY website: http://www.chiark.greenend.org.uk/~sgtatham/putty/download.
you must install the HP Graphics and USB Combo Card to use a GUI console. No other graphics card is supported by HP Integrity servers. Also, only HP keyboards are supported with this card. Figure 1-2 shows a GUI console connected to an HP Integrity server. Figure 1-2 GUI Console Configuration A GUI console provides complete access to all installation and administration tasks that you can perform on the server.
5. 6. Select Select Active Console Output Devices. Highlight the line with the graphics card PCI device. If the line does not begin with an asterisk, the device is disabled. Use the space bar to change the state of the card from disabled to enabled (as indicated by the asterisk). 7. 8. Select Save Settings to NVRAM; and then, Exit. The video display is now directed to the GUI console. The set up is complete. Proceed to the GUI Console installation process: “Install from a GUI Console” (page 39).
2. 3. 4. 5. 6. Enter your user name and password to log in to the System Management Homepage. On the Administration tab, select Licensing in the left panel. Enter the license number. In the Remote Console tab, select Integrated Remote Console in the left panel. Click Launch. (If Launch is grayed out, the license might be invalid or expired.) A new window displays, providing access to the IRC.
Figure 1-3 PXE/WDS Configuration NOTE: When you perform a PXE/WDS headless installation, note the following: • Headless installations using PXE/WDS are not supported with Windows Server 2008 R2. Use the HP Reinstallation media instead. • Do not connect the WDS server to the Integrity server using your intranet during initial Windows OS installation. Set up a small private network, populated with the WDS server, a hub, and the system LAN NIC of the HP Integrity server.
Install WDS You can install WDS using the Control Panel or an unattended Setup answer file. To install WDS using Add or Remove Programs, follow these steps: 1. 2. Click Start → Settings → Control Panel, double-click Add or Remove Programs, and select Add/Remove Windows Components to install the WDS component. Open the WDS Setup Wizard, and click Next. The WDS Setup wizard prompts you for information about specific settings used in the WDS installation. The wizard prompts you to follow these steps: a.
6. To specify where to create the client computer account, click one of the following options: • Default directory service location • Same location as the user setting up the client computer • The following directory service location 7. If you choose the last option in Step 6, click Browse, and specify where to create the computer accounts. Authorize a WDS Server in Active Directory A WDS server must be authorized in Active Directory to respond to clients requesting service.
installation of Windows Server 2008 R2 will wipe out the current installation (there is no upgrade path to Windows 2008 R2; the new installation completely overwrites the existing one). Follow these steps to set up the server hardware for OS installation. Set Up the Boot Drive The OS installs, through the boot controller detected as adapter zero, to the drive detected as drive zero. CAUTION: HP strongly recommends that only the target OS drive is connected during installation.
1. From the EFI Shell, enter the reconnect –r command. The reconnect command reconnects drivers from a device, disconnecting drivers from all devices and then reconnecting them. If you do not specify a device handle, the reconnect operation is performed on all handles in the system. If you specify a device handle, only the device handle and the devices following it are reconnected. 2. From the EFI Shell, enter the map -r command. The -r option regenerates all mappings in a system.
1. From the EFI Shell, enter the acpiconfig command. EFI displays the current ACPI settings. If the flag is set to windows, EFI displays the text, acpiconfig: windows. 2. 3. If the flag is not set to windows, enter the acpiconfig windows command. Enter the acpiconfig command again, to display the settings again, and verify that the flag is set correctly. NOTE: Updating the system firmware can reset this flag to default. Verify that the flag is set to windows, after you flash the system firmware.
2 Installing the OS This chapter provides instructions for installing the operating system (OS) using a headless console, a GUI console, or a Preboot Execution Environment (PXE) enabled network interface card (NIC). This chapter also provides reinstallation instructions for Windows Server 2008 R2. Each method comprises a series of tasks, concluding with two tasks that verify that the OS was installed correctly. You must install the HP Integrity Support Pack after installing the OS.
3. 4. 5. From the EFI Boot Manager Boot Menu, select Internal Bootable DVD, and press Enter. EBSU starts and displays the Welcome screen. Click OK, and press Enter. From the Main Menu, select Express Setup and press Enter. Figure 2-1 EBSU Main Menu NOTE: In rx7640/rx8640/Superdome cellular systems, and in BL860c i2/BL870c i2/BL890c i2/rx 2800 i2 server blades, the EBSU Main Menu includes the Pre-OS Configuration Checking option. In other systems, this option is not available.
Figure 2-2 EBSU Firmware Update Screen NOTE: You might not be able to use EBSU to flash the firmware of some devices. You cannot flash the firmware if the installed version is the same or higher than the version on the Smart Setup media. 8. EBSU displays the partition disk screen. Select ESP + HPSP + MSR or ESP Only. HP recommends the default (ESP + HPSP + MSR) as a way to simplify the maintenance of your server. Figure 2-3 EBSU Partition Disk Screen 9. EBSU displays the install options screen.
Integrity Offline Diagnostics CD) in the HPSP partition. Also specify which version of the Windows OS Installer to launch (in this case: Windows Server 2008 R2). Then select Next and press Enter. Figure 2-4 EBSU Install Options Screen NOTE: In BL860c i2/BL870c i2/BL890c i2/rx 2800 i2 server blades, this screen does not include the Windows Server 2008 SP2 option. 10. EBSU prompts you to execute an unattended Windows Server 2008 installation. Press Yes to continue. Figure 2-5 EBSU Prompt Screen 11.
Figure 2-6 EBSU Product Key Screen 13. EBSU displays a warning that all partitions on the disk will be overwritten. Select Continue and press Enter. 14. EBSU displays a warning that a temporary MSDATA partition will be created. Press Enter. 15. EBSU displays an informational pop-up that the installation will begin. Press Enter. 16. The installation begins and progresses through partition creation and firmware updates. Insert the HP Integrity Offline Diagnostics CD when prompted, then press Enter.
Figure 2-7 EBSU Screen #1 18. When EBSU prompts you, insert the Microsoft Windows Server 2008 R2 operating system CD and press Enter. Figure 2-8 EBSU Screen #2 19. Press any key when prompted to boot from the CD or DVD (be ready to do this quickly, or the system could time out). 20. Windows begins loading files from the disk. When the progress bar reaches 100%, the screen displays the message: The CMD command is available. 21. Type cmd to launch a CMD prompt session. 22.
Figure 2-9 EBSU Screen #3 NOTE: In BL860c i2/BL870c i2/BL890c i2/rx 2800 i2 server blades and not shown in the above image, there are two more files (delthisvolume.cmd and readme1st.txt) and two more directories ($WinPEDriver and data). 24. Type install.cmd to begin. 25. Press the Esc + Tab keys to open a different command channel. Verify there are no error messages in the SACSetupErr channel. Figure 2-10 EBSU Screen #4 26. The system will restart during the installation.
29. Type the following: wmic RDToggle where ServerName="hostname" call SetAllowTSConnections 1 This command enables display of the remote desktop. Figure 2-12 EBSU Screen #6 30. The system finishes booting to the Desktop for the first time and launches the Initial Configuration Tasks screen. Figure 2-13 Initial Configuration Tasks Screen 31.
• • Enable Remote Desktop Configure Windows Firewall You must configure some of these settings, to prepare your system for its intended use in your production environment. However, it is beyond the scope of this document to make specific recommendations, as each user has a unique combination of factors such as system I/O, storage, intended use, and so on. See your System Administrator and the operating system online help. 32. Installation of the OS is complete.
Figure 2-14 EBSU Main Menu NOTE: In rx7640/rx8640/Superdome cellular systems, and in BL860c i2/BL870c i2/BL890c i2/rx 2800 i2 server blades, the EBSU Main Menu includes the Pre-OS Configuration Checking option. In other systems, this option is not available. Also, in BL860c i2/BL870c i2/BL890c i2 server blades, the EBSU Main Menu does NOT include the Install/Update Support Tools option. 6. 7. 40 EBSU displays a screen with special instructions for RAID users.
Figure 2-15 EBSU Firmware Update Screen NOTE: You might not be able to use EBSU to flash the firmware of some devices. You cannot flash the firmware if the installed version is the same or higher than the version on the Smart Setup media. 8. EBSU displays the partition disk screen. Select ESP + HPSP + MSR, or ESP Only. HP recommends the default (ESP + HPSP + MSR) as a way to simplify the maintenance of your server. Figure 2-16 EBSU Partition Disk Screen 9. EBSU displays an install options screen.
Integrity Offline Diagnostics CD) in the HPSP partition. Also, specify which version of the Windows OS Installer to launch (in this case, Windows Server 2008 R2). Then, select Next and press Enter. Figure 2-17 EBSU Install Options Screen NOTE: In BL860c i2/BL870c i2/BL890c i2/rx 2800 i2 server blades, this screen does not include the Windows Server 2008 SP2 option. 10. EBSU prompts you to execute an unattended Windows Server 2008 installation. Press No to continue. Figure 2-18 EBSU Prompt Screen 11.
13. In BL860c i2/BL870c i2/BL890c i2/rx 2800 i2 server blades, EBSU displays information that a temporary MSDATA partition will be created. After reading, press Enter. 14. EBSU displays an informational pop-up that the installation will begin. Press Enter. 15. The installation begins and progresses through partition creation and firmware updates. Insert the HP Integrity Offline Diagnostics CD when prompted, then press Enter.
18. Press any key when prompted to continue (be ready to do this quickly or the system could time-out). 19. Windows begins loading files from the disk. When the progress bar reaches 100%, the Install Windows screen displays. Select your default language, time and currency formats, and keyboard or input method, then click Next. Figure 2-21 Install Windows Screen #1 20. 21. 22. 23. 24. 44 At the next screen, click Install Now. At the next screen, enter your product key again and click Next.
Figure 2-22 Install Windows Screen #2 25. At the next pop-up screen, click Next to continue. Installation of the operating system begins. 26. When the installation finishes, you are prompted to change your password to log on the first time. Click OK. 27. Enter the new system administrator password twice and click the arrow button. 28. The password change is confirmed. Click OK to continue. 29. The system finishes booting to the desktop for the first time and launches the Initial Configuration Tasks screen.
Figure 2-23 Initial Configuration Tasks Screen 30. At this screen, you can set up and configure system-wide settings, and perform tasks such as: • Set time zone • Configure networking • Provide computer name and domain info • Enable automatic updating and feedback • Download and install updates • Add roles • Add features • Enable Remote Desktop • Configure Windows Firewall You must configure some of these settings, to prepare your system for its intended use in your production environment.
3. 4. 5. 6. “Apply OS Updates Using the Smart Update Media” (page 54) “Enable Windows Components” (page 55) “Verify System Device Drivers and Register for Updates” (page 56) To determine whether you need to perform any additional tasks, see “Miscellaneous Installation Issues” (page 57). Then, see the sections describing configuration of the management tools, and perform these tasks: 1. “Configure System Management Homepage” (page 66) 2. “Configure and Verify the WBEM Providers” (page 64) 3.
NOTE: The default MP “user name/password” is “Administrator/Admin” for BL8x0 i2 and rx2800 i2 server blades, and “Admin/Admin” for all other servers. 4. 5. Type co and press Enter. Deletion of existing Windows Boot Manager entries is recommended. To delete boot entries, choose one of the following methods: • Use the EFI Maintenance menu: — If you are using the Enhanced EFI Boot Manager Menu (gray background), select EFI Boot Manager Menu → Boot Configuration → Remove Boot Entry.
errors and repeat this procedure over again from the beginning. If the installation was successful, the system displays: Reinstall Finished [OK]. 22. At the prompt, press a letter from the menu displayed (E = Exit; R = Reboot; S = Restart the restore process) and press Enter to proceed. 23. Go to the next section for instructions on how to specify the server settings and complete the reinstallation.
NOTE: On systems with an Integrated Lights-Out management processor, you can connect remotely to the target server first (using the instructions provided in this section: “Set Up an Integrated Remote Console” (page 22)), and then follow the reinstallation instructions provided in this section. Load the System Image to the Boot Disk To reinstall Windows Server 2008 R2 from the local GUI console, follow these steps: 1. Configure your boot controller and drive.
15. When all files from the DVD drive are copied to the server boot disk, read the displayed message. If there were any errors during this process you must address the cause of those errors and repeat this procedure over again from the beginning. If the installation was successful, the system displays: Reinstall Finished. Click OK to continue. 16. At the prompt, press a letter from the menu displayed (E = Exit; R = Reboot; S = Restart the restore process) and press Enter to proceed. 17.
To activate the OS, follow these steps: 1. 2. 3. Click Start. Right-click Computer and select Properties. The System window displays. Scroll down to the Windows Activation section at the bottom of the window and click x days until automatic activation. Activate Windows now. Figure 2-24 System Window #1 NOTE: If you click Change product key instead of Activate Windows now you are prompted to enter the key and then the Activation wizard runs.
Figure 2-25 Windows Activation Screen 6. 7. The Activation screen displays a progress bar and the message: This might take a few minutes. During this time, the system attempts to connect to the internet. If it cannot connect, you are prompted to setup an Internet connection. In this situation you must follow the on-screen instructions and disregard the rest of this procedure because it assumes you have a valid internet connection. When the process finishes, the screen displays: Activation was successful.
8. Confirm the activation by going back to the System window and looking at the activation section at the bottom. It should indicate: Windows is activated. Figure 2-26 System Window #2 Apply OS Updates Using the Smart Update Media Install the latest OS and security updates from the HP Smart Update media. You can find the Smart Update media in the Insight Foundation suite for Integrity with Windows kit with the Smart Setup media.
10. Click Install to continue with the installation or click Close to exit setup. When you click Install, a command window appears, listing each update as it installs. Sometimes these are large updates that can take several minutes each to install. 11. When prompted, click Reboot to complete the installation. HP recommends rebooting after each QFE bundle installs to ensure correct installation. 12. To read a detailed description about an update, click on its Knowledge Base (KB) ID number.
2. 3. 4. In the Server Summary section, click Configure Remote Desktop. On the Remote tab, select the desired RDC connection option and assign user access rights as needed. Click Apply and then OK to apply the changes. To enable remote desktop connections from a headless server, follow these steps: 1. 2. 3. 4. 5. Go to the SAC console. Log in as Administrator. At the SAC> prompt, enter cmd. Press Esc+Tab to enter the Command Prompt console.
NOTE: A yellow bang might appear under Non-Plug and Play Drivers in the Windows Device Manager when hidden devices are enabled. The yellow bang appears only if the Show hidden devices option is enabled under the Non-Plug and Play Drivers in the Windows Device Manager. If no serial legacy device is found in the system, the OS generates a yellow bang for the Serial option. 5.
Smart Update media after the OS installation, in order to obtain the latest HP value-added software (drivers, tools, utilities, manageability agents) for HP Integrity Servers. Installing Windows Server 2008 R2 on rx8640 and rx7640 Servers On rx8640 and rx7640 servers, you must run the reconnect –r command at the EFI shell before launching the Windows Server 2008 R2 installation.
NOTE: When enabled, hyperthreading is activated for all CPUs in the system. You cannot apply hyperthreading to a single CPU, cell, or nPartition. To enable hyperthreading on partitionable and nonpartitionable HP Integrity servers using the Extensible Firmware Interface (EFI), follow these steps: 1. 2. 3. 4. Reboot the system to the EFI Shell. Issue the cpuconfig threads command. The system indicates whether hyperthreading is turned ON or OFF.
1. At the EFI shell prompt, run the System Security Configuration command by typing secconfig tpm off and pressing Enter. The following (or similar) text should display on-screen: SYSTEM SECURITY CONFIGURATION TPM: Enabled TPM Next Boot Status: Disabled TPM Vendor ID: 0x15D1 TPM Product ID: 0x000B TPM TCG Spec Version: 1.2.1.0 secconfig: A reset is required for security configuration changes to take effect. 2. 3. 60 At the shell prompt, run the Reset command by typing reset and pressing Enter.
3 Installing and Configuring the Management Tools This chapter describes how to install the tools, applications, and drivers needed to manage your Integrity server. Install the Integrity Support Pack (ISP) This procedure describes how to install the Integrity Support Pack locally (onto the same system that the SmartSetup CD is inserted into).
8. 9. The Discovery Progress screen displays as HPSUM checks the system to see which components are currently installed. When the discovery process finishes, the Select Bundle Filter screen displays and lists the Integrity Support Packs that were found on the Smart Setup media. Select HP Integrity Support Pack for Windows Server 2008 R2 on Itanium-based Systems (if multiple Integrity Support Packs are available, you must select the one marked “2008 R2”). Also select “FORCE ALL BUNDLE UPDATES”.
Figure 3-3 HPSUM Select Items to be Installed Screen Install the Integrity Support Pack (ISP) 63
11. When the installation finishes, the Installation Results screen appears. You might be prompted to reboot the server to complete the installation of some components. Even if you are not prompted, reboot the server by clicking Reboot Now. Figure 3-4 HPSUM Installation Results Screen The latest Integrity Support Pack can also be downloaded from the HP Integrity server support website: http://www.hp.com/support/itaniumservers/. On the Technical Support page, click on your Integrity server model number.
NOTE: Concurrent installation of the WBEM Providers (from Smart Setup version 6.5 or later) and the HP Insight Management Agents (from earlier versions of Smart Setup) is not supported. If the HP Insight Management Agents were previously installed on the system, you must manually uninstall them before installing the version 6.5 WBEM Providers. If the system has Management Agents version 6.2, you can upgrade from WBEM Providers 6.2 to 6.5 without manually uninstalling Agents 6.2 first.
Enable Auto Page Refresh and Set the Interval You can configure SMH with an Auto Refresh interval to get updates from the WBEM Providers. To enable WBEM Auto Refresh and to set the Refresh interval, follow these steps: 1. 2. 3. Click Settings → Auto Refresh → Configure Page Refresh Settings. Select a refresh interval between 5 seconds and 30 minutes. Use the radio button to enable Auto Refresh. After WBEM Auto Refresh is enabled, the browser refreshes the pages at the specified interval.
1. 2. 3. 4. Click Help on the System Management Homepage. Click System Management Homepage Help. On the left navigation bar, select Settings Tab → Security. Change these settings as necessary for your system and production environment. The SMH Settings tab allows you to set some parameters. This capability requires security that includes the three predefined users. For agents running on Microsoft operating systems, there are no default passwords.
(page 81). For a description of nPartitioning and associated tools and concepts, see the nPartition Administrator's Guide found here: http://h20000.www2.hp.com/bc/docs/support/SupportManual/c02058520/c02058520.pdf Verify nPartition Commands 1. Perform a local management test by opening a command prompt window and issuing the following command: C:\Documents and Settings> parstatus -X If you run this command on an nPartition, it displays information about the local server’s nPartition configuration.
3. To test remote WBEM connections, do the following: a. Copy the remote nPartition WBEM certificate into the local WBEM trusted certificate store. b. Enter the host name and IP address of the remote nPartition that you want to connect to, along with an account and password with administrative privileges on the remote nPartition in the top half of the Partition Manager login screen. c. Click OK. 4. In order to test remote IPMI connections, do the following: a.
A Preparing the Server for Microsoft SQL Server This appendix describes the server configuration tasks needed to install Microsoft SQL Server.
4. Verify storage/Fibre Channel HBAs: a. Maximum queue depth: Ensure that the HP AH402A or AH403A (Emulex) driver options set in LPutil are equal to or greater than the number of physical drives (default = 20). b. Maximum queue depth: For HP AH400A or AH401A (Qlogic) NVRAM, ensure that the Sanblade execution throttle setting is equal to or greater than the number of physical drives (default = 16). c. Enable write cache: It is important to have a cached log for the database.
5. 6. 7. 8. 9. 10. 11. 12. 13. 14. 15. 16. 17. 18. 19. 20. 21. On the Welcome page of the SQL Server Installation Wizard, click Next. On the System Configuration Check (SCC) page, the installation computer is scanned for conditions that may block setup. To interrupt the scan, click Stop. To display a list of check items grouped by result, click Filter and then select a category from the drop-down list. To view a report of SCC results, click Report and then select an option from the drop-down list.
B EFI Utilities This appendix provides an overview of the Extensible Firmware Interface (EFI) and the EFI-Based Setup Utility (EBSU). The EFI provides access to the server before the operating system (OS) stage, which enables you to flash the firmware, partition the hard disk, install diagnostic tools, configure storage controllers, and run other EFI utilities. Introduction to EFI EFI is an interface between operating system, firmware, and hardware.
Common EFI Shell Commands The following table lists common EFI commands. Table B-1 EFI Shell Commands and Descriptions Command Description Boot Commands autoboot Set and view the autoboot timeout variable. bcfg Display and modify the driver and boot configuration. boottest Set and view BootTest bits. dbprofile Display and modify direct boot profiles for use by lanboot. lanboot Boot over the LAN. reconfigreset Reset the system (nPartition) for reconfiguration.
Table B-1 EFI Shell Commands and Descriptions (continued) Command Description connect Bind a driver to a device. dblk Hex dump – BlkIo devices. devices Display devices managed by EFI drivers. devtree Display tree of devices. dh Dump handle information. disconnect Disconnect drivers from devices. drivers Display list of drivers. drvcfg Invoke the Driver Configuration Protocol. drvdiag Invoke the Driver Diagnostics Protocol. guid Dump known GUID IDs. lanaddress Display the MAC address.
Table B-1 EFI Shell Commands and Descriptions (continued) Command Description Memory Commands Commands for listing and managing memory, EFI variables, and NVRAM details. default Set default NVRAM values. dmem Dump memory or memory-mapped I/O. dmpstore Display EFI variables. memmap Display the memory map. mm Display and modify MEM/IO/PCI. pdt View and clear nPartition or cell memory page de-allocation table (PDT).
• — Installing offline diagnostic tools — Installing Windows Maintain Firmware — Maintains the firmware for selected devices with flashable firmware. You can flash devices individually or all at once. NOTE: You cannot flash the firmware if the installed version is the same as, or higher, than the version on the Smart Setup media. Also, you cannot use EBSU to flash the system firmware and System Management Firmware (iLO firmware) of Integrity BL860c i2/BL870c i2/ BL890c i2 server blades.
— — • Efifmt. Formats the disk for use with EFI. Efichk. Checks the disk and displays a status report. This tool fixes some disk errors and recovers readable information from the disk. Install/Update Support Tools — Copies support tools to the HPSP partition and installs a Python interpreter. These tools are for use only by HP Support. Integrity BL860c i2/BL870c i2/BL890c i2 server blades do not need these tools.
C nPartitioning This appendix introduces node partitions (nPartitions) on cell-based HP Integrity servers running Microsoft® Windows® Server 2008 and describes the tools to manage them. A cell-based HP Integrity server (such as the rx7640, rx8640, or Superdome) can be configured as a single system or partitioned into several independent systems.
Getting to Know nPartitions Partitions are physical or logical mechanisms for demarcating operational environments within a single system or across multiple systems. Partitioning lets you consolidate systems, allocate computing resources in response to fluctuations in demand, maximize resource use, and protect operating environments from disruptive events. Partitioning Continuum HP offers a continuum of partitioning technologies, as shown in Figure C-2.
The hardware of a cell-based server—including cells, I/O expansion cabinets, cables, cabinet hardware, fans, and power and utility components—is known as a server complex: • A Superdome server complex can consist of one or two server cabinets and can include one or two I/O expansion cabinets (which provide additional I/O chassis). • An rx8640 server complex consists of a single server cabinet and can include one I/O expansion cabinet (which provides two additional I/O chassis).
I/O chassis with core I/O), only one core I/O is actively used in an nPartition. System firmware selects the core cell in the early stages of the nPartition boot process. When none of the core cell choices can serve as the active core cell, the nPartition attempts to select an eligible cell. The core I/O in the I/O chassis connected to the core cell provides console access for the nPartition through the management processor.
3. I/O discovery, and discovery of interconnecting fabric (connections between the cell and other cells, I/O, and system crossbars). The firmware completes self-tests and discovery, reports the hardware configuration of the cell to the management processor (MP), informs the MP that the cell is “waiting at BIB,” and then waits for the cell BIB flag to be cleared. nPartition Boot Phase After its cells have completed their self-tests, the nPartition is booted.
Management processor (MP) menus Management processor menus provide a service interface that provides access to all hardware and nPartitions in the complex. The MP is always available, whether or not nPartitions are configured or booted in the server complex. Management Interface Options You can manage nPartitions remotely using one of two management interfaces: the Intelligent Platform Management Interface (IPMI) and the Web-Based Enterprise Management (WBEM) infrastructure.
The nPartition Provider caches the static data and reuses it for subsequent requests so that future command usage does not incur that initial overhead. If the PC is rebooted or the nPartition Provider is restarted, the cached data is lost. The first request to the MP after the restart requires the same initial overhead. IPMI specifies that data be sent as UDP datagrams over the LAN. UDP does not guarantee delivery of datagrams.
data in a consistent fashion. Client applications can then use this information to manage an enterprise computing environment. Because WBEM supports a distributed management architecture, client applications (nPartition management tools, for example) can run on a remote system and use the WBEM infrastructure to send requests to managed servers. Partition Manager is a WBEM client application. Partition Manager uses WBEM when retrieving information about a server complex.
Running Partition Manager Using WBEM You can run Partition Manager with WBEM in one of two ways: • If you are running Partition Manager on an nPartition: Select the Switch Complexes task from the Tools menu. In the resulting dialog, enter the host name or IP address of the remote nPartition, and supply a user name and that user’s password. To display information about the target complex, specify a user defined on the remote nPartition.
• Simple installation: Install all components on an nPartition (fewer components must be installed manually when reinstall media is used). • Simple connection: Log in to SMH and run Partition Manager, or run nPartition commands with no -g/-u options. No additional authentication or login steps are required to manage the local complex. • Controlled configuration of specific nPartitions with the nPartition Config Privilege option: You can restrict to configuration of certain nPartitions.
• Authentication is implemented by the OS login to the nPartition (the account used to log in to Windows on the nPartition where the tools are run). • For Partition Manager (a web application), you are prompted for login credentials when you first access an SMH or Partition Manager web page (locally or from a remote browser).
Setting up the Management Station A management station is often used to configure and administer nPartitions on an HP Integrity server. If HP provided your management station (for example, the PC-SMS management system supplied with Superdome servers), then nPartition tools and support components are installed.
To execute nPartition commands using a telnet connection to the management station, do the following: 1. Invoke telnet on the remote terminal, providing the host name or IP address of the management station. 2. Log in to the telnet server with a valid user name and password. 3. From the command prompt, execute nPartition commands as usual. NOTE: The OS might limit the number of telnet connections permitted into the management station.
IO ID List connections from cells to I/O chassis on HP Superdome servers. List product and serial numbers. Using the EFI Shell EFI Shell methods for listing hardware and nPartition status include the following commands. Hardware and nPartition information displayed by the EFI Shell is limited to the local nPartition. info sys List the local nPartition number and active cell details. List the I/O configuration. info io info mem List memory details. info cpu List processor details.
Modifying nPartitions Modifying an nPartition involves using an nPartition administration tool to revise parts of the server Complex Profile data, which determines how hardware is assigned to and used by nPartitions: • Use parmodify or Partition Manager from an nPartition running in the same complex as the nPartition. You can also modify some nPartition details locally from an nPartition console by using EFI Shell commands.
Modifying nPartitions includes the following tasks: • Assign (add) or unassign (remove) cells from an nPartition: — In the Partition Manager Hardware tab, select an nPartition and cell and then select nPartition → Assign cell(s) / Cell → Assign cell(s) or nPartition → Unassign cell(s) / Cell → Unassign cell(s). — Alternatively, use the parmodify -p# -a#... command to add a cell or the parmodify -p# -d#... command to remove a cell from the nPartition (-p#, where # is the partition number).
Using the MP Command Menu The MP provides the following commands, available from the Command menu, to support boot and reset operations: RS Reset an nPartition. Reset an nPartition after self-tests and partition rendezvous are complete. RR Perform a shutdown for reconfig of an nPartition. Reset an nPartition after self-tests and partition rendezvous are complete. BO Boot the cells assigned to an nPartition past the waiting at BIB state and begin the nPartition boot phase.
On mid-range servers, the default behavior is for shutdown /s to cause nPartition hardware to be powered off. Use the EFI Shell command acpiconfig disable softpowerdown instead to make cells remain at a wait at BIB state.
D SMH and the WBEM Providers The WBEM Providers are a group of services that report system health and status information back to the System Management Homepage (SMH) application, where it can be monitored by the System Administrator. They are installed by default when you install the Integrity Support Pack. WBEM is a Web-based approach for exchanging data across different technologies and platforms.
• System thresholds • Diagnostics • Software version control for an individual server Before you can start using SMH you must first complete the tasks described earlier in this document, found here: “Configure and Verify the WBEM Providers” (page 64). NOTE: This section is not intended to be an SMH tutorial. For a complete instructions on how to use this tool, see the HP System Management Homepage User Guide, found here: http:// www.hp.
Header Frame The Header Frame is constantly visible regardless of the page you are viewing. Data frame The Data Frame displays the status for HP Management software and utilities on the system. The following informational areas and links appear in the Header Frame: • Master header: The links show the path you are viewing, the user, and a Sign Out link. • Menu. Each item is a direct link to a page or section including: — Home — Settings — Tasks — Tools — Logs — Webapps — Support — Help • Main title area.
— — • • • • • • • • If the user is operating system-based, a Sign Out link displays. If anonymous access is enabled, the Current User displays hpsmh_anonymous and the Sign In link displays. — If Local Access is enabled, the Current User displays hpsmh_local_anonymous or hpsmh_local_administrator, depending on what level of access has been enabled, and local access appears below user type. — If user type is local_access_administrator, no Sign In or Sign Out link displays.
Unknown Informational • Management Processor: Displays a link to the Remote Insight Lights-Out Edition (RILOE) board or the Integrated Lights-Out (iLO) board. This information is provided by the WBEM Providers. If no WBEM Providers are installed, none displays. The SMH Home Page The Home page provides system, subsystem, and status views of the server. Information on the Home page is provided by the integrated Web-Based Enterprise Management (WBEM) property pages and management utilities.
Operating System Category The Operating System category contains links that show basic operating system configuration, usage, state, and other information. The Operating System category displays the following information: • Logical Disks: Information includes volume, free space, queue length, and disk busy time. Network Category The Network category contains links that display basic network system configuration, usage, state, and other information.
information that includes device serial number and asset tag. Provides firmware versions including index, description, revision, location, and status. • • • • Complex-wide Info: Provides server complex information, including total number of cabinets, number of compute cabinets, number of IOX cabinets, complex name, and partition number. Crash Dump Monitoring: Allows you to enable or disable the monitoring of a crash dump condition.
E Headless Windows Installations Users of Microsoft Windows Server 2008 R2 are familiar with the setup, installation, and operation of systems using a keyboard, video, and mouse. However, these users might not be familiar with the set of headless functionality provided by HP Integrity servers. Integrity servers provide a set of tools to set up, install, manage, and use the system in a headless manner.
For future systems there may be many customized partitions that require careful allocation of IO slots. Avoiding the consumption of slots for non-critical use such as graphics will ease the deployment of future systems. Customers should start to deploy and operate systems using headless methods. How to Access a Headless System Users have full access to the GUI of a system through the use of Remote Desktop. From any client PC on the network, running the Terminal Services Client (mstsc.
This path can host multiple channels of communication, from firmware messages at power-on to a command-line interface when the OS has booted. In Integrity systems, this EMS port is connected to the MP and is accessible from the management LAN or management serial port. Firmware Redirection When the server powers on, the system firmware is responsible for configuring all hardware and loading EFI. This phase is also called FW or BIOS console redirection.
Cellular Systems There are two options for changing network parameters in cellular systems: • Systems can be connected to the LAN one at a time and the user can use telnet to connect to the factory default IP address and change the network address. After this address is changed, the next system can be connected to the LAN without creating an address conflict. • The user can use the management serial port and connect a terminal or a PC running a terminal emulator such as Hyperterm.