HP Integrity Windows Server 2008 R2 and Windows Server 2008 SP2 Hardware Administrator's Guide v6.5
NOTE: Do not open the manual retention latch (MRL) before the LED stops blinking. A
fatal machine check alert (MCA) error can occur.
3. Open the MRL.
4. Remove the card.
5. Close the MRL.
Identifying Hardware Location String
The Windows Device Manager reports the hardware location in the following format:
CBHSS = value
where value is a numeric string that starting from the left indicates the cabinet number, bay
number, chassis number, and two-digit slot number. For example, CBHSS = 81107 indicates
cabinet 8, bay 1, chassis 1, and slot 07.
NOTE: The Windows OS does not show leading 0s. For example, if CBHSS = 1107 is displayed,
it denotes cabinet 0, bay 1, chassis 1, and slot 7.
10 Performing Hot-Plug Operations