HP Integrity Servers with Microsoft Windows Server 2008 SP2 Release Notes v6.5

Target LUN and boot controller WWN not visible in a VC environment
Issue When installing to storage attached to an Emulex LPe1105 mezzanine controller
(403621-B21) in a Virtual Connect (VC) environment through a Brocade switch,
the target LUN is not visible and the WWN for the boot controller is not visible
in the zone in the switch administrative tool.
Servers HP Integrity BL860c Server Blade and BL870c Server Blade
Workaround Write down and save the controller World-Wide Number (WWN) when
installing it into the system, or obtain it from the VC manager or EFI utility.
Then, manually enter the WWN into the desired zone on the switch when
configuring the zone. Scan for targets and continue with the usual installation
steps to boot from the controller. For more information, see the HP StorageWorks
Booting Windows for Itanium-based systems from a storage area network document
at http://www.hp.com.
HP Smart Update Manager
hpsum_swdiscovery.exe application crash
Issue After upgrading the Integrity Support Pack from version 6.2 to 6.5, the
hpsum_swdiscovery.exe tool can crash.
Servers All Integrity
Workaround
1. Navigate to the C:\CPQSYSTEM\cpxml folder.
2. Move all of the files to a temporary location.
3. Run HP-SUM again.
4. Copy the files from the temporary location to the C:\CPQSYSTEM\cpxml
folder.
If any pop-up windows display that contain the sw_discovery.exe
application name, follow these steps:
1. Navigate to the C:\Program Files\HPWBEM\Tools folder.
2. Replace the hpsum_swdiscovery.exe file with the same file in the
Support Pack that you downloaded.
hpsum_swdiscovery.exe application error
Issue
Version 3.4.3.0 of the hpsum_swdiscovery.exe tool can cause an Application
Error that is reported in the Windows Event Log.
Servers All Integrity
Workaround
1. Navigate to the C:\CPQSYSTEM\cpxml folder.
2. Remove the cp009280.xml file.
3. Restart SMH.
If any pop-up windows display that contain the sw_discovery.exe
application name, follow these steps:
1. Navigate to the C:\Program Files\HPWBEM\Tools folder.
2. Replace the hpsum_swdiscovery.exe file with the same file in the
Support Pack that you downloaded.
Qlogic driver does not install successfully
Issue If you have multiple Qlogic cards in your system, HPSUM might not update
the driver for some of the cards.
Servers All Integrity
Troubleshooting Common Issues 21