HP Integrity Servers with Microsoft Windows Server 2008 Release Notes v6.2

No server information displayed on the System Management Homepage
Issue Occasionally after a system reboot, the HP Insight Management Agents do not
return any server hardware information. Therefore, the System Management
Homepage does not show any server hardware information.
Servers All Integrity
Workaround Restart the HP Insight Server Agents service.
Network Interface Cards (NICs)
AD385A NIC card can affect server performance under a load
Issue When handling IPv6 traffic, a server with the Neterion AD385A NIC card
installed can exhibit sluggish performance. In some cases, a DPC Watchdog
timeout event occurs.
Servers Superdome SX2000, rx8640, rx7640, rx6600, rx3600, rx2660
Workaround
Set the RssBaseCpu registry value in HLKM\System\CurrentControlSet\
Services\NDIS\Parameters to 8 (the default is 4). For more information,
see the Receive-Side Scaling Enhancements in Windows Server 2008 white paper at
http://www.microsoft.com/whdc/device/network/NDIS_RSS.mspx
Smart Array
Blue screen displays when Smart Array cards are hot removed
Issue A blue screen is displayed when Smart Array P800/E500 and P400 cards are hot
removed with no storage attached.
Servers All supported Integrity servers
Workaround HP does not recommend any hot replace or hot add functions for these cards
in the 6.2 release.
System Management Homepage (SMH)
Software Information page in SMH is blank
Issue After upgrading the Integrity Support Pack from Version 6.1 to Version 6.2, the
Software Information page in System Management Homepage (SMH) is empty
(blank page).
Servers All Integrity
Workaround
1. Navigate to the C:\CPQSYSTEM\cpxml folder.
2. Remove the cp009280.xml file.
3. Restart SMH.
If any pop-up windows display that contain the sw_discovery.exe
application name, follow these steps:
1. Navigate to the C:\Program Files\HPWBEM\Tools folder.
2. Replace the hpsum_swdiscovery.exe file with the same file in the
Support Pack that you downloaded.
Video
HPSUM screen cannot be resized
Issue When installing the Integrity Service Pack (ISP), the HPSUM screen cannot be
resized.
Troubleshooting Common Issues 23