HP Integrity Servers with Microsoft Windows Server 2008 Release Notes v6.1

it identifies the installed driver is same as the available version and does not
execute the installation.
Servers All Integrity
Workaround Run HPSUM with force option. See the Installation Guide.
Management Agents
Error event after firmware update
Issue When a system firmware bundle update is applied on an Integrity server rx6600
using the “HP Integrity Server rx3600/rx6600 System, BMC, iLO-2 MP, FPGA,
and PsoC Firmware Bundle” HP Package, an error event might be logged in
the Windows System Event Log. The The HP Insight Foundation Agent
service hung on starting event is logged because the underlying
baseboard management controller is taking longer to respond to data requests
from the agents service.
Servers rx6600
Workaround The event is logged only once during system reboot following the firmware
update. The Foundation Agent service operation is not affected.
Error during installation over the same version or earlier version
Issue HP Insight Management Agents installation returns an error when being
installed over the same version or when being downgraded to an older version.
Servers All Integrity
Workaround There is no workaround. These are unsupported operations.
No server information displayed on the System Management Homepage
Issue Occasionally after a system reboot, the HP Insight Management Agents do not
return any server hardware information. Therefore, the System Management
Homepage does not show any server hardware information.
Servers All Integrity
Workaround Restart the HP Insight Server Agents service.
Smart Array
Blue screen displays when Smart Array cards are hot removed
Issue A blue screen is displayed when Smart Array P800/E500 and P400 cards are hot
removed with no storage attached.
Servers All supported Integrity servers
Workaround HP recommends that you not perform hot replace and hot add functions in the
6.1 release.
Video
HPSUM screen cannot be resized
Issue When installing the Integrity Service Pack (ISP), the HPSUM screen cannot be
resized.
Servers rx2660
Workaround Before running HPSUM, install the HP Integrity Video driver smart component
(cp008457.exe) before installing the Integrity Support Pack.
22 Release 6.1 Overview