HP Insight Management WBEM Providers for Windows on Integrity Data Sheet

Host Attached SATA Provider 560
Table 23-43 HP_SATADeviceIndication: Disk Drive status Degraded
Property name Property implementation
DeviceModel Physical Disk Model string
23.4.6Physical Drive Status Changed to Predictive Failure
Table 23-44 HP_SATADeviceIndication: Disk Drive status Predictive Failure
Property name Property implementation
CIM_Indication
IndicationIdentifier GUID string generated at indication
PerceivedSeverity 3 (Degraded/Warning)
IndicationTime Time of indication
CIM_AlertIndication
Description A Disk Drive status has changed to Predictive Failure.
AlertingManagedElement WBEM path of the HP_SATADiskDrive class
AlertingElementFormat 2 (CIMObjectPath)
AlertType 5 (Device Alert)
EventID 605
ProviderName HP SATA
RecommendedActions Replace drive immediately to avoid loss of data.
SystemName Name of the computer system generating the indication
SystemCreationClassName CreationClassName of the computer system generating
the indication
HP_AlertIndication
Summary Physical drive status Predictive Failure.
EventCategory 6 (Primary Storage Device)
ProbableCause 1 (Other)
ProbableCauseDescription Disk Drive State Changed to Predictive Failure
NetworkAddresses Contains a list of all the IP addresses (IPv4 and IPv6) of
the computer system generating the indication
69 (Windows 2003 32-bit)
OSType
70 (Windows 2003 64-bit)
76 (Windows 2008 32-bit)
77 (Windows 2008 64-bit)
103 (Windows 2008 R2)
OSVersion Operating system version of the computer system
generating the indication in the format,
major.minor.build