HP Insight Management WBEM Providers for Windows on Integrity Data Sheet
Host Attached SATA Provider 556
Table 23-41 HP_SATADeviceIndication: Disk Drive status OK
Property name Property implementation
SystemProductID Product ID of the computer system generating the
indication
SystemModel Model name of the computer system generating the
indication
SystemGUID Platform GUID of the computer system generating the
indication
• 3 (Enclosure) for c-Class blade systems
ImpactedDomain
• 4 (System) for all other systems
When ImpactedDomain is 3 (Enclosure), the following
properties (indicated with *) are populated.
BladeBay * HP_BladeCSLocation.LocationInformation[0]
BladeName * HP_WinComputerSystem.Name
EnclosureName * HP_BladeEnclosureCS.Name
RackName * Rack name if one exists
RackUID * Rack Unique Identifier if one exists
SystemVirtualSerialNumber Conditional property containing the virtual system
serial number string when running in a Virtual Connect
environment
SystemVirtualUUID Conditional property containing the virtual system
UUID when running in a Virtual Connect environment
HP_HardwareIndication
HP_DeviceIndication
DeviceModel Physical Disk Model string
23.4.4Physical Drive Status Changed to Error
Table 23-42 HP_SATADeviceIndication: Disk Drive status Error
Property name Property implementation
CIM_Indication
IndicationIdentifier GUID string generated at indication
PerceivedSeverity 6 (Critical)
IndicationTime Time of indication
CIM_AlertIndication
Description A Disk Drive status has changed to 'Error'.
AlertingManagedElement WBEM path of the HP_SATADiskDrive class
AlertingElementFormat 2 (CIMObjectPath)
AlertType 5 (Device Alert)