HP Insight Management WBEM Providers for Windows on Integrity Data Sheet

Host Attached SATA Provider 553
Table 23-39 HP_SATADeviceIndication: New Disk Drive found
Property name Property implementation
SystemVirtualSerialNumber Conditional property containing the virtual system
serial number string when running in a Virtual Connect
environment
SystemVirtualUUID Conditional property containing the virtual system
UUID when running in a Virtual Connect environment
HP_HardwareIndication
HP_DeviceIndication
DeviceModel Physical Disk Model string
23.4.2Physical Drive Status Changed to unknown
Table 23-40 HP_SATADeviceIndication: Disk Drive status unknown
Property name Property implementation
CIM_Indication
IndicationIdentifier GUID string generated at indication
PerceivedSeverity 2 (Informational)
IndicationTime Time of indication
CIM_AlertIndication
Description A Disk Drive status has changed to Unknown.
AlertingManagedElement WBEM path of the HP_SATADiskDrive class
AlertingElementFormat 2 (CIMObjectPath)
AlertType 5 (Device Alert)
EventID 601
ProviderName HP SATA
RecommendedActions Check the Disk Drive driver and WMI providers and
ensure that the correct versions of this software are
installed properly.
SystemName Name of the computer system generating the indication
SystemCreationClassName CreationClassName of the computer system generating
the indication
HP_AlertIndication
Summary Disk Drive status Unknown
EventCategory 6 (Primary Storage Device)
ProbableCause 1 (Other)
ProbableCauseDescription Disk Drive status changed to 'Unknown'