HP Insight Management WBEM Providers for Windows on Integrity Data Sheet

Host Attached SATA Provider 538
Table 23-6 Class: HP_SATAPortControllerPhysicalPackage (CIM_PhysicalPackage)
Property name Property implementation
Description Controller name. For example:
Standard Dual Channel PCI IDE Controller
CIM_ManagedSystemElement
Name “Standard Dual Channel PCI IDE Controller”
CIM_PhysicalElement
CreationClassName HP_SATAPortControllerPhysicalPackage
Manufacturer Populated with the manufacturer property value of the
IDE controller device.
PartNumber Not available for this implementation
SerialNumber Populated with Controller PNPDeviceID
For example:
PCI\VEN_8086&DEV_3A22&SUBSYS_330B103C&RE
V_00\3&11583659&0&FA
Tag Opaque key
Version Not available for this implementation
CIM_PhysicalPackage
RemovalConditions 2 (Not Applicable)
HP_SATAPortControllerPhysicalPackage
23.3.6HP_SATADiskPhysicalPackage
HP_SATADiskPhysicalPackage represents the physical aspects of the disk drive. There is one instance
per disk drive.
Table 23-7 Class: HP_SATADiskPhysicalPackage (CIM_PhysicalPackage)
Property name Property implementation
CIM_ManagedElement
ElementName A short textual description of the disk drive. For
example:
FB160C4081 ATA Device
Maxtor 6Y080M0 ATA Device
CIM_ManagedSystemElement
Name \\.\PHYSICALDRIVE0
CIM_ PhysicalElement
CreationClassName HP_SATADiskPhysicalPackage