HP Insight Management WBEM Providers for Windows on Integrity Data Sheet
Standalone Tape Drive Profile 515
Table 21-34 HP_TapeDriveDeviceIndication: Failed Drive Now Missing
Property name Property implementation
CIM_Indication
IndicationIdentifier GUID string generated at indication
PerceivedSeverity 2 (Informational)
IndicationTime Time of indication
CIM_AlertIndication
Description See HPWMITapeEventMetaData.mof
AlertingMangedElement WBEM Path of HPSCSI_TapeDrive class instance
AlertingElementFormat 2 (CIMObjectPath)
AlertType 5 (Device Alert)
EventID 508 (Failed drive now missing)
EventTime Time of the event or time of the indication if the event
time is unknown.
ProviderName HP Tape
RecommendedActions See HPWMITapeEventMetaData.mof
SystemName Name of the computer system generating the indication
SystemCreationClassName CreationClassName of the computer system generating
the indication.
HP_AlertIndication
Summary See HPWMITapeEventMetaData.mof
EventCategory 7 (Secondary Storage Device)
ProbableCause 73 (Element Missing)
ProbableCauseDescription Missing tape drive that was Failed
ProviderVersion Provider version generating the indication in the form,
major.minor.revision.build
NetworkAddresses Contains a list of all the IP addresses (IPv4 and IPv6) of
the computer system generating the indication
• 69 (Windows 2003 32-bit)
OSType
• 70 (Windows 2003 64-bit)
• 76 (Windows 2008 32-bit)
• 77 (Windows 2008 64-bit)
• 103 (Windows 2008 R2)
OSVersion Operating system version of the computer system
generating the indication in the form,
major.minor.build
SystemFirmwareVersion Firmware version of the computer system generating
the indication.