HP Insight Management WBEM Providers for Windows on Integrity Data Sheet

Standalone Tape Drive Profile 511
Table 21-31 HP_TapeDriveDeviceIndication: Drive status changed to Failed
Property name Property implementation
SystemFirmwareVersion Firmware version of the computer system generating
the indication.
SystemSerialNumber Serial number of the computer system generating the
indication.
SystemProductID Product ID of the computer system generating the
indication.
SystemModel Model name of the computer system generating the
indication.
SystemGUID Platform GUID of the computer system generating the
indication.
3 (Enclosure) for c-Class blade systems
ImpactedDomain
4 (System) for all other systems
HP_HardwareIndication
HWFirmwareVersion Enclosure F/W version string (It must match the
HP_TapeDriveFirmware.VersionString)
HWManufacturer Enclosure Manufacturer string
HWSerialNumber Enclosure Serial Number (It must match the
HP_StorageEnclosure.SerialNumber)
HP_DeviceIndication
DeviceModel Enclosure Model string
HP_TapeDriveDeviceIndication
21.4.6Tape Drive status changed to Offline
Table 21-32 HP_TapeDriveDeviceIndication: Tape Drive status changed to Offline
Property name Property implementation
CIM_Indication
IndicationIdentifier GUID string generated at indication
PerceivedSeverity 6 (Critical)
IndicationTime Time of indication
CIM_AlertIndication
Description See HPWMITapeEventMetaData.mof
AlertingMangedElement WBEM Path of HPSCSI_TapeDrive class instance
AlertingElementFormat 2 (CIMObjectPath)
AlertType 5 (Device Alert)
EventID 506 (Tape drive status changed to Offline)