HP Insight Management WBEM Providers for Windows on Integrity Data Sheet
Standalone Tape Drive Profile 508
Table 21-29 HP_TapeDriveDeviceIndication: Drive status changed to Degraded
Property name Property implementation
HWFirmwareVersion Enclosure F/W version string (It must match the
HP_TapeDriveFirmware.VersionString)
HWManufacturer Enclosure Manufacturer string
HWSerialNumber Enclosure Serial Number (It must match the
HP_StorageEnclosure.SerialNumber)
HP_DeviceIndication
DeviceModel Enclosure Model string
HP_TapeDriveDeviceIndication
21.4.4Drive status changed to Failed
Table 21-30 HP_TapeDriveDeviceIndication: Drive status changed to Failed
Property name Property implementation
CIM_Indication
IndicationIdentifier GUID string generated at indication
PerceivedSeverity 6 (Critical)
IndicationTime Time of indication
CIM_AlertIndication
Description See HPWMITapeEventMetaData.mof
AlertingMangedElement WBEM Path of HPSCSI_TapeDrive class instance
AlertingElementFormat 2 (CIMObjectPath)
AlertType 5 (Device Alert)
EventID 504 (Tape drive status changed to Failed)
EventTime Time of the event or time of the indication if the event
time is unknown.
ProviderName HP Tape
RecommendedActions See HPWMITapeEventMetaData.mof
SystemName Name of the computer system generating the
indication.
SystemCreationClassName CreationClassName of the computer system generating
the indication.
HP_AlertIndication
Summary See HPWMITapeEventMetaData.mof
EventCategory 7 (Secondary Storage Device)
ProbableCause 35 (Performance Degraded)