HP Insight Management WBEM Providers for Windows on Integrity Data Sheet
SCSI HBA 475
Table 18-79 HPSCSI_DeviceIndication: Fan status change—OK
Property name Property implementation
IndicationIdentifier GUID string generated at time of indication
PerceivedSeverity 2 (Info)
IndicationTime Time of indication
CIM_AlertIndication
Description The storage enclosure fan subsystem is operating
properly.
AlertingMangedElement WBEM path of the HPSCSI_StorageEnclosureProcessor
class instance
AlertingElementFormat 2 (CIMObjectPath)
AlertType 5 (Device Alert)
EventID 304
EventTime Time of the event or time of the indication if event time
unknown.
ProviderName HP SCSI
RecommendedActions No action is recommended.
SystemName Name of the computer system generating the indication
SystemCreationClassName CreationClassName of the computer system generating
the indication
HP_AlertIndication
Summary Fan status OK
EventCategory 24 (Primary Storage Cooling)
ProbableCause 1 (Other)
ProbableCauseDescription Fan Status Changed to OK
ProviderVersion Provider version generating the indication, in the form:
major.minor.revision.build.
NetworkAddresses A list of all the IP addresses (IPv4 and IPv6) of the
computer system generating the indication
• 69 (Windows Server 2003 32-bit)
OSType
• 70 (Windows Server 2003 64-bit)
• 76 (Windows Server 2008 32-bit)
• 77 (Windows Server 2008 64-bit)
• 103 (Windows Server 2008 R2)
OSVersion Operating system version of the computer system
generating the indication in the format,
major.minor.build
SystemFirmwareVersion Firmware version of the computer system generating
the indication