HP Insight Management WBEM Providers for Windows on Integrity Data Sheet

SCSI HBA 463
Table 18-73 HPSCSI_DeviceIndication: Power Supply status NOT REDUNDANT
Property name Property implementation
AlertingMangedElement WBEM path of the HPSCSI_StorageEnclosureProcessor
class instance
AlertingElementFormat 2 (CIMObjectPath)
AlertType 5 (Device Alert)
EventID 301
EventTime Time of the event or time of the indication if event time
unknown.
ProviderName HP SCSI
RecommendedActions Check status of all enclosure power supplies. Ensure
that power supplies have not failed. Add or replace
power supplies as necessary.
SystemName Name of the computer system generating the indication
SystemCreationClassName CreationClassName of the computer system generating
the indication
HP_AlertIndication
Summary SCSI Storage Enclosure operating with no Redundant
Power Supply
EventCategory 17 (Primary Storage Power)
ProbableCause 88 (Loss of Redundancy)
ProbableCauseDescription Redundant Power Supply Status Changed to Non-
Redundant
ProviderVersion Provider version generating the indication, in the form:
major.minor.revision.build.
NetworkAddresses A list of all the IP addresses (IPv4 and IPv6) of the
computer system generating the indication
69 (Windows Server 2003 32-bit)
OSType
70 (Windows Server 2003 64-bit)
76 (Windows Server 2008 32-bit)
77 (Windows Server 2008 64-bit)
103 (Windows Server 2008 R2)
OSVersion Operating system version of the computer system
generating the indication in the format,
major.minor.build
SystemFirmwareVersion Firmware version of the computer system generating
the indication
SystemSerialNumber Serial number of the computer system generating the
indication
SystemProductID Product ID of the computer system generating the
indication