SCSI HBA 462
Table 18-72 HPSCSI_DeviceIndication: Controller status ERROR
Property name Property implementation
SystemGUID Platform GUID of the computer system generating the
indication
3 (Enclosure) for c-Class blade systems
ImpactedDomain
4 (System) for all other systems
When ImpactedDomain is 3 (Enclosure), the following
properties (indicated with *) are populated.
BladeBay * HP_BladeCSLocation.LocationInformation[0]
BladeName * HP_ComputerSystem.Name
EnclosureName * HP_BladeEnclosureCS.Name
RackName * Rack name if one exists
RackUID * Rack Unique Identifier if one exists
SystemVirtualSerialNumber Conditional property containing the virtual system
serial number string when running in a Virtual Connect
environment.
SystemVirtualUUID Conditional property containing the virtual system
UUID when running in a Virtual Connect environment.
HP_HardwareIndication
HWFirmwareVersion Controller firmware version string
HWLogicalLocation Controller Location string
HWSerialNumber Controller Serial Number
HP_DeviceIndication
DeviceModel Controller Model string
18.4.12Power Supply Status NOT REDUNDANT
Note: This indication might not be generated because the SCSI firmware does not report this
indication.
Table 18-73
HPSCSI_DeviceIndication: Power Supply status NOT REDUNDANT
Property name Property implementation
CIM_Indication
IndicationIdentifier GUID string generated at time of indication
PerceivedSeverity 5 (Major)
IndicationTime Time of indication
CIM_AlertIndication
Description A Storage Enclosure Power Supply status has changed
to non-redundant.