HP Insight Management WBEM Providers for Windows on Integrity Data Sheet

SCSI HBA 443
Table 18-62 HPSCSI_DeviceIndication: Physical Drive status set to OK
Property name Property implementation
SystemGUID Platform GUID of the computer system generating the
indication
3 (Enclosure) for c-Class blade systems
ImpactedDomain
4 (System) for all other systems
When ImpactedDomain is 3 (Enclosure), the following
properties (indicated with *) are populated.
BladeBay * HP_BladeCSLocation.LocationInformation[0]
BladeName * HP_ComputerSystem.Name
EnclosureName * HP_BladeEnclosureCS.Name
RackName * Rack name if one exists
RackUID * Rack Unique Identifier if one exists
SystemVirtualSerialNumber Conditional property containing the virtual system
serial number string when running in a Virtual Connect
environment.
SystemVirtualUUID Conditional property containing the virtual system
UUID when running in a Virtual Connect environment.
HP_HardwareIndication
HWFirmwareVersion Disk firmware version string
HWLogicalLocation Disk Location string
HWManufacturer Disk Manufacturer string
HWSerialNumber Disk Serial Number
HP_DeviceIndication
DeviceModel Disk Model string
18.4.2Physical Drive Status Set to ERROR
Table 18-63 HPSCSI_DeviceIndication: Physical Drive status set to ERROR
Property name Property implementation
CIM_Indication
IndicationIdentifier GUID string generated at time of indication
PerceivedSeverity Severity (for example, 5 (Major))
IndicationTime Time of indication
CIM_AlertIndication
Description A SCSI physical drive has a status of Error.
AlertingMangedElement WBEM path of the HPSCSI_DiskDrive class instance
AlertingElementFormat 2 (CIMObjectPath)