HP Insight Management WBEM Providers for Windows on Integrity Data Sheet

SCSI HBA 442
Table 18-62 HPSCSI_DeviceIndication: Physical Drive status set to OK
Property name Property implementation
Description A SCSI physical drive status has changed from non-OK
to OK.
AlertingMangedElement WBEM path of the HPSCSI_DiskDrive class instance
AlertingElementFormat 2 (CIMObjectPath)
AlertType 5 (Device Alert)
EventID 4
EventTime Time of the event or time of the indication if event time
unknown.
ProviderName HP SCSI
RecommendedActions No action is recommended.
SystemName Name of the computer system generating the indication
SystemCreationClassName CreationClassName of the computer system generating
the indication
HP_AlertIndication
Summary Physical Disk OK
EventCategory 6 (Primary Storage)
ProbableCause 59 (Previous event cleared)
ProbableCauseDescription Physical Drive OK
ProviderVersion Provider version generating the indication, in the form:
major.minor.revision.build.
NetworkAddresses A list of all the IP addresses (IPv4 and IPv6) of the
computer system generating the indication
69 (Windows Server 2003 32-bit)
OSType
70 (Windows Server 2003 64-bit)
76 (Windows Server 2008 32-bit)
77 (Windows Server 2008 64-bit)
103 (Windows Server 2008 R2)
OSVersion Operating system version of the computer system
generating the indication in the format,
major.minor.build
SystemFirmwareVersion Firmware version of the computer system generating
the indication
SystemSerialNumber Serial number of the computer system generating the
indication
SystemProductID Product ID of the computer system generating the
indication
SystemModel Model name of the computer system generating the
indication