HP Insight Management WBEM Providers for Windows on Integrity Data Sheet
SCSI HBA 417
Table 18-4 Class: HPSCSI_DiskDrive (CIM_DiskDrive)
Property name Property implementation
DriveConfiguration 4 (Non RAID)
• True—drive can report MNP Data
DriveHasMNPData
• False—drive does not report MNP Data
DriveInterface 1 (Parallel SCSI)
• 0 (Unknown)—drive placement cannot be
determined
DrivePlacement
• 1 (Internal)—drive is internal to host
• 2 (External)—drive is contained in external
enclosure
DriveRotationalSpeed Speed in rpm
NegotiatedDataWidth Bus width in bits
NegotiatedSpeed Current bus speed in bits per second
HPSCSI_DiskDrive
SMARTSupport Indicates whether the disk support SMART feature or
not.
Action Indicates the status of the physical disk.
18.3.4HPSCSI_StorageExtent
HPSCSI_StorageExtent represents the consumable storage that is available on a disk drive. There is
one instance per disk drive.
Table 18-5 Class: HPSCSI_StorageExtent (CIM_StorageExtent)
Property name Property implementation
CIM_ManagedElement
ElementName Disk name (for example, SCSIBUS:1 SCSIID:0)
CIM_ManagedSystemElement
Name Serial number of drive
• 0 (Other)
OperationalStatus[0]
• 2 (OK)
• 5 (Predictive Failure)
• 6 (ERROR)
StatusDescriptions Description of the Operational Status (the reason
OperationalStatus is set)
CIM_LogicalElement
CIM_EnabledLogicalElement
EnabledDefault 2 (Enabled)
EnabledState 5 (Not Applicable)